Error description
Currently if SIM(A) is used Cloning Tool executes ALTER TABLE ALTER COLUMN restart for identity columns even during simulation. We should implement the following logic: If DDL-ENABLE(N) and SIM(A) we will just generate ALTER TABLE for identity columns and will not execute it. If DDL-ENABLE(Y) and SIM(A) we will use the same PROCESS-TYPE for actions with generated DDL and ALTER TABLE for identity columns. If DDL-ENABLE(Y), PROCESS-TYPE(N), and SIM(A) then we will not execute DDL and ALTER TABLE for identity columns.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Cloning Tool * **************************************************************** * PROBLEM DESCRIPTION: Currently if SIM(A) is used Cloning * * Tool executes ALTER TABLE ALTER COLUMN * * restart for identity columns even * * during simulation. * * We should implement the following * * logic: * * If DDL-ENABLE(N) and SIM(A) we will * * just generate ALTER TABLE for identity * * columns and will not execute it. * * If DDL-ENABLE(Y) and SIM(A) we will * * use the same PROCESS-TYPE for actions * * with generated DDL and ALTER TABLE for * * identity columns. * * If DDL-ENABLE(Y), PROCESS-TYPE(N), and * * SIM(A) then we will not execute DDL * * and ALTER TABLE for identity columns. * **************************************************************** * RECOMMENDATION: * **************************************************************** Code has been changed to fix this problem
Problem conclusion
Apply the PTF for problem resolution
Temporary fix
Comments
APAR Information
APAR number
PI87592
Reported component name
DB2 CLONING TOO
Reported component ID
5655N1000
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-09-19
Closed date
2017-09-28
Last modified date
2017-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI50734
Modules/Macros
CKZ00136 CKZ00547 CKZ00781
Fix information
Fixed component name
DB2 CLONING TOO
Fixed component ID
5655N1000
Applicable component levels
R320 PSY UI50734
UP17/09/30 P F709
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
12 February 2021