A fix is available
APAR status
Closed as new function.
Error description
During QCF UNLOAD, active destination(s) are stopped by QCF through the issuing of IMS /STO commands. Customers may not want active destination(s) to be stopped so this APAR will provide a new QCF keyword for the TOIPARMS statement to allow users to enable or disable the issuing of IMS stop commands.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of QCF 3.2 * **************************************************************** * PROBLEM DESCRIPTION: During a QCF UNLOAD job, if QCF * * encounters active destination(s), it * * will create and issue IMS /STO * * commands. Some customers may not want * * active destination(s) to be stopped. * **************************************************************** * RECOMMENDATION: * **************************************************************** During a QCF UNLOAD job, if QCF encounters active destination(s), it will create and issue IMS /STO commands. Some customers may not want active destination(s) to be stopped.
Problem conclusion
Temporary fix
Comments
Install the APAR to receive the enhancement done to the TOIPARMS statement which allows the user to specify the ENABLESTOP keyword (to allow QCF to continue to issue IMS /STO commands) or the DISABLESTOP keyword (to disable QCF from issuing IMS /STO commands) against active destination(s) during a QCF UNLOAD job.
APAR Information
APAR number
PI87212
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
320
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-09-12
Closed date
2017-11-06
Last modified date
2017-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI51708
Modules/Macros
IQCF25 IQCH72A IQCI70 IQCM2ENU IQCP0000 IQCP7000 IQCP7100 IQCP7110 IQCP72A IQCP7200 IQCP7210 IQCP7220 IQCP7230 IQCP8000 IQCP8100 IQCP8110 IQCP8200 IQCP8210 IQCP9000 IQCXGUN6 IQCXJOIN IQCXREAD
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R320 PSY UI51708
UP17/11/08 P F711
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Edition":"","Line of Business":{"code":"","label":""}}]