A fix is available
APAR status
Closed as program error.
Error description
ABENDS0C4 in FPXEWPR0 when running ODE unload job after APAR PI66194 PTF UI40446 is installed. Also ABENDU3504 was received in FPXPROC0 as a result of the S0C4. ABEND U3504
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of Online Data Extract (ODE) of * * HPFPU Fast Path Online Tools in Fast Path * * Solution Pack Version 1 Release 3 * * (FMID: HAHQ130). * **************************************************************** * PROBLEM DESCRIPTION: FPO Online Data Extract (ODE) abended * * with ABENDS0C4 in FPXEWPR0 after * * installing PI66194/UI40446. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** After installing PI66194/UI40446, ODE abended with S0C4 in FPXEWPR0 or FPXEWRD0. This issue may occur when the size of work buffer is greater than or equal to 16M bytes. The size is calculated as follows: (UOW1 + IOVFPOOL) * CISIZE * 2 A code defect in size adjustment makes the size to be an odd number, which causes a deviation in the data pointer.
Problem conclusion
ODE has been modified to adjust the size of work buffer to a multiple of 16 when it is greater than or equal to 16M bytes.
Temporary fix
Comments
APAR Information
APAR number
PI87065
Reported component name
IMS FP SOLUTION
Reported component ID
5655W1400
Reported release
130
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-09-08
Closed date
2017-09-12
Last modified date
2017-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI50247
Modules/Macros
FPXINITB FPXINITC FPXINITD FPXINITE FPXINIT5
Fix information
Fixed component name
IMS FP SOLUTION
Fixed component ID
5655W1400
Applicable component levels
R130 PSY UI50247
UP17/09/13 P F709 Ø
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Fast Path Solution Pack"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130"}]
Document Information
Modified date: