A fix is available
APAR status
Closed as program error.
Error description
If a TRUNCATE IMMEDIATE is issued but fails and is rolled back, the logged UR contains a sequence of DB2 Diagnostic records and UR Control records that is not handled properly by IIDR CDC for z/OS. A problem is detected and an SDUMP is issued. Since this is a day one defect, the content of the dump title could vary considerably, and so cannot be used to identify requisites for the problem.
Local fix
To get past this problem, either use SETLOGPOS to bypass the UR in the log, or refresh all tables in the subscription so that the portion of the log where the TRUNCATE IMMEDIATE appears will no longer be accessed by the subscription.
Problem summary
**************************************************************** * USERS AFFECTED: Users of IIDR CDC for z/OS. * **************************************************************** * PROBLEM DESCRIPTION: If a TRUNCATE IMMEDIATE is issued but * * fails to complete, the data logged is * * not processed correctly by IIDR CDC for * * z/OS. It interprets the logged data as * * inappropriate, requests an SDUMP, and * * terminates the subscription. * **************************************************************** * RECOMMENDATION: APPLY CORRECTIVE SERVICE * **************************************************************** A failed TRUNCATE IMMEDIATE SQL statement will cause IIDR CDC for z/OS to request an SDUMP and terminate the subscription.
Problem conclusion
Logic has been ammended to recognize and process a failed TRUNCATE IMMEDIATE correctly.
Temporary fix
Comments
APAR Information
APAR number
PI86937
Reported component name
INFO SRVR CDC Z
Reported component ID
5655U7600
Reported release
A21
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-09-06
Closed date
2017-09-22
Last modified date
2017-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI50542
Modules/Macros
CHCSTGSP
Fix information
Fixed component name
INFO SRVR CDC Z
Fixed component ID
5655U7600
Applicable component levels
RA21 PSY UI50542
UP17/10/12 P F710
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
01 November 2017