APAR status
Closed as unreproducible in next release.
Error description
Running the z/OS Connect EE build toolkit (zconbt) to create a SAR file for the WOLA SP, with useChannel=true specified in the properties file, the build toolkit issues the following messages: BAQB0001I: Creating service archive from configuration file <dir_path_your.properties> BAQB0013E: Unexpected error has occurred: null If zconbt is run with -verbose parameter, it indicates a NullPointerException has occurred as indicated by the following output: java.lang.NullPointerException at com.ibm.zosconnect.buildtoolkit.SARGenerator.save(Unknown Source) at com.ibm.zosconnect.buildtoolkit.cli.BuildToolkit.main(Unknown Source) Additional words: msgBAQB0001I BAQB0001 msgBAQB0001 msgBAQB0013E BAQB0013 msgBAQB0013 zconbt.zip
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of the z/OS Connect EE Build * * Toolkit producing SAR files for use with * * the WOLA Service Provider * **************************************************************** * PROBLEM DESCRIPTION: A properties file that specifies * * useChannel=true might fail to * * create a SAR file and output message * * BAQB0013E * **************************************************************** A properties file that specifies useChannel=true might fail to create a SAR file and output the following message: BAQB0013E: Unexpected error has occurred: null Specifying the -verbose flag when running the build toolkit reports that a NullPointerException has occurred.
Problem conclusion
Temporary fix
Comments
The reported problem cannot be recreated using the build toolkit supplied with version 3.0.2 of z/OS Connect EE.
APAR Information
APAR number
PI86420
Reported component name
Z/OS CONNECT EE
Reported component ID
5655CE300
Reported release
000
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-08-25
Closed date
2017-10-20
Last modified date
2017-10-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
Z/OS CONNECT EE
Fixed component ID
5655CE300
Applicable component levels
R000 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSNPJM","label":"IBM z\/OS Connect"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
14 February 2023