Error description
Unknown results can occur when adding a new record object to a dynamic array that also calls an external program
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * For cobolGen users, unusual results can occur, even an * * abend, if trying to use a "new" on a record that has a set * * values block that calls a library function. * **************************************************************** * PROBLEM DESCRIPTION: * * If a "new" is done against a record and a set values * * expression is present that calls a library function, then it * * is possible that problems can occur. This will only happen * * if the library callout also causes a garbage collection to * * occur. The problem is that the address of the new temporary * * record is saved across the library call, but the address was * * never registered to the heap memory manager. When a garbage * * collection occurs, it updates known pointers to the new * * location of the moved memory. In this case however, the * * address used was not from a pointer, but from an old linkage * * section reference. This caused the reference to be invalid * * and hence the problem. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The software was updated to restored the linkage section reference from a heap managed variable, which causes the reference to be valid.
Temporary fix
Comments
APAR Information
APAR number
PI86399
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-08-25
Closed date
2019-01-18
Last modified date
2019-01-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R901 PSY
UP
R911 PSY
UP
R950 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
18 October 2021