PI86383: ASMA144E BEGIN-TO-CONTINUE COLUMNS NOT BLANK IN STAGE2 SYSGEN PROCESSING WHICH INCLUDES MSC CAUSING RC08

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ASMA144E Begin-to-continue columns not blank in STAGE2 SYSGEN
    processing which includes MSC causing RC08
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All IMS V15 MSC users using MSPLINK MACRO to define MSC      *
    * (TCPIP) links in IMS SYSGEN Stage 1 with long parameter      *
    * names.                                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Error message ASMA144E was received IMS SYSGEN Stage 2 when  *
    * MACRO DFSLCB was generating a LCB control block entry.       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * INSTALL CORRECTIVE SERVICE FOR APAR/PTF                      *
    ****************************************************************
    MSPLINK macro is used to define MSC physical links in the IMS
    system definition. TCPIP link has multiple  parameters.
    Parameters NAME, LCLICON, and LCLPLKID could be 1-8 characters
    long. If a longer parameter name is chosen, the source code
    building LCB control block can be generated by MACRO DFSCOMM1
    with good RC, but the code's format might be incorrect.
    
    At Stage 2, MACRO DFSLCB is invoked to generate MSC link control
    block from the source code generated at Stage 1. If the input
    parameters to DFSLCB are within column 72, STAGE 2 can run
    successfully. Otherwise error message ASMA144E is issued  to
    indicate 'Begin-to-continue columns not blank' and STAGE 2
    failed also with RC 8. The customer encountered this error as
    the passed parameters were beyond column 72. But the problem was
    caused earlier at Stage 1.
    

Problem conclusion

  • Macro DFSCOMM1 has been enhanced to
    1. punch " DFSLCB &PNAM,&FLG1,&FLG2,&LNR,CTT&CTTW,&DCB," with
    continuation character ";" at column 72.
    2. punch the rest parameters.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI86383

  • Reported component name

    IMS V15

  • Reported component ID

    5635A0600

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-08-25

  • Closed date

    2018-02-23

  • Last modified date

    2018-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI54043

Modules/Macros

  • DFSCOMM1
    

Fix information

  • Fixed component name

    IMS V15

  • Fixed component ID

    5635A0600