PI86251: EXECUTOR DOESN'T FUNCTION IF STARTED QUICKLY AFTER STOPPING ON AIX

Fixes are available

9.0.0.6: WebSphere Application Server traditional V9.0 Fix Pack 6
8.5.5.13: WebSphere Application Server V8.5.5 Fix Pack 13
9.0.0.7: WebSphere Application Server traditional V9.0 Fix Pack 7
9.0.0.8: WebSphere Application Server traditional V9.0 Fix Pack 8
8.5.5.14: WebSphere Application Server V8.5.5 Fix Pack 14
9.0.0.9: WebSphere Application Server traditional V9.0 Fix Pack 9
9.0.0.10: WebSphere Application Server traditional V9.0 Fix Pack 10
8.5.5.15: WebSphere Application Server V8.5.5 Fix Pack 15
9.0.0.11: WebSphere Application Server traditional V9.0 Fix Pack 11
9.0.5.0: WebSphere Application Server traditional Version 9.0.5 Refresh Pack
9.0.5.1: WebSphere Application Server traditional Version 9.0.5 Fix Pack 1
9.0.5.2: WebSphere Application Server traditional Version 9.0.5 Fix Pack 2
8.5.5.17: WebSphere Application Server V8.5.5 Fix Pack 17
9.0.5.3: WebSphere Application Server traditional Version 9.0.5 Fix Pack 3
9.0.5.4: WebSphere Application Server traditional Version 9.0.5 Fix Pack 4
9.0.5.5: WebSphere Application Server traditional Version 9.0.5 Fix Pack 5
WebSphere Application Server traditional 9.0.5.6
9.0.5.7: WebSphere Application Server traditional Version 9.0.5 Fix Pack 7
9.0.5.8: WebSphere Application Server traditional Version 9.0.5.8
8.5.5.20: WebSphere Application Server V8.5.5.20
8.5.5.18: WebSphere Application Server V8.5.5 Fix Pack 18
8.5.5.19: WebSphere Application Server V8.5.5 Fix Pack 19
9.0.5.9: WebSphere Application Server traditional Version 9.0.5.9
9.0.5.10: WebSphere Application Server traditional Version 9.0.5.10
8.5.5.16: WebSphere Application Server V8.5.5 Fix Pack 16
8.5.5.21: WebSphere Application Server V8.5.5.21
9.0.5.11: WebSphere Application Server traditional Version 9.0.5.11

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Executor start reports success but functions fails when start
    is issued after a stop
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  IBM WebSphere Application Server Edge Load  *
    *                  Balancer for IPv4 and IPv6 users on AIX     *
    ****************************************************************
    * PROBLEM DESCRIPTION: After a successfully "executor start"   *
    *                      subsequenty commands may all fail       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    If the executor is started following an "executor stop"
    command, the module may not have been completely unloaded and
    the "executor start" reports success because it detects the
    module is already loaded. Since the module is actually in the
    process of unloading, subsequent commands will fail.
    

Problem conclusion

  • Code has been corrected to wait and allow the module to be
    unloaded before the "executor stop" reports a successful unload.
    
    Fix levels :
       8.5.5.13
       9.0.0.6
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI86251

  • Reported component name

    WS EDGE LB IPV4

  • Reported component ID

    5724H8812

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-08-23

  • Closed date

    2017-08-25

  • Last modified date

    2017-08-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WS EDGE LB IPV4

  • Fixed component ID

    5724H8812

Applicable component levels

  • R850 PSY

       UP

  • R900 PSY

       UP