IBM Support

PI85933: FPA AND FPO SHOULD ISSUE AN ERROR MESSAGE TO INDICATE ABEND/RSN CODES FROM EDIT/COMPRESSION ROUTINE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • FPA and FPO should issue an error message to indicate abend/rsn
    code from edit / compression routine.
    
    Keywords: fast path advanced online abend reason
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Fast Path Solution Pack Version *
    *                 1 Release 3 (FMID: HAHQ130).                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. Fast Path Advanced Tool and Fast     *
    *                      Path Online Tools should issue an error *
    *                      message to indicate abend/rsn code from *
    *                      edit/compression routine.               *
    *                      2. Fast Path Advanced Tool Reload       *
    *                      function issued the HFPP0006E message.  *
    *                      3. FPO ODE should issue the OPEN and    *
    *                      CLOSE call to the edit/compression      *
    *                      routine only when INIT is specified     *
    *                      in the COMPRTN keyword.                 *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    1. When abend occurred in edit/compression routine, it is
    difficult to identify the error sometimes. Fast Path Advanced
    Tool and Fast Path Online Tools have been modified to issue
    an error message to indicate abend/rsn code from
    edit/compression routine.
    
    2. FPA Reload function failed with the HFPP0006E message when
    it restarted from the image copy processing for the third restar
    mode execution sometimes, due to inconsistency in the checkpoint
    file. FPA Reload function has been modified to remove the
    inconsistency between the checkpoint records.
    
    3. ODE issued the OPEN and CLOSE call to the edit/compression
    routine without checking if INIT is specified in the COMPRTN
    keyword. ODE has been modified to issue these calls only when
    INIT is specified.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI85933

  • Reported component name

    IMS FP SOLUTION

  • Reported component ID

    5655W1400

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-08-15

  • Closed date

    2017-09-20

  • Last modified date

    2017-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI50474

Modules/Macros

  • FPXEXPNB FPXEXPNC FPXEXPND FPXEXPNE FPXEXPN5
    FPXMSG00 HFPINTF0 HFPPRII0 HFPSGDDB HFPSGDDC HFPSGDDD HFPSGDDE
    HFPSGDD5 HFPTECL0 HFPWMTT0
    

Publications Referenced
SC19401003    

Fix information

  • Fixed component name

    IMS FP SOLUTION

  • Fixed component ID

    5655W1400

Applicable component levels

  • R130 PSY UI50474

       UP17/09/22 P F709

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Fast Path Solution Pack"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: