IBM Support

PI85386: DISPLAY PROBLEM OF ADMINCONSOLE AT "INTERNALCLASSESACCESSMODE"

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • For the parameters of "access to internal server classes",
    there are cases where setting values are not displayed
    correctly
    depending on screen route.
    
    When "access to internal server class" is set to "restrict",
    
    Routes indicated correctly as "restrict":
    Top screen> (From left menu) Server> Server type>
    WebSphere Application Server> Target Application Server name
    
    Case where the actual is "restrict", but it seems to be
    "Allow":
    Top screen> (From left menu) Server> All servers> Target
    application
    server
    
    It is seen as a problem of screen display.
    
    * Background/Goal:
    Both routes behave similarly.
    * Date and Time/Frequency:
    Always.
    * Reproduction Steps:
    I believe that you can reproduce in your environment using
    AdminConsole.
    
    1(Preparation):
    *Show at Admin Console
    Top screen> (From left menu) Server> Server type>
    WebSphere Application Server> Target Application Server name
    * Change  "access to internal server classes" to ""restrict"
    * Press OK to save the setting.
    2. Please confirm that the settings visible from the
    following
    screen
    are different.
    Routes indicated correctly as "restrict":
    Top screen> (From left menu) Server> Server type>
    WebSphere Application Server> Target Application Server name
    Case where the actual is "restrict", but it seems to be
    "Allow":
    Top screen> (From left menu) Server> All servers>
    Target application server
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server WAS ND edition- Virtual              *
    *                  Enterprise/IM Component                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: InternalClassAccess mode not correct    *
    *                      when server is visited from all servers *
    *                      page                                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When accessing a Websphere Server from the All Servers page, the
    internal access mode drop down does not reflect the true state.
    The correct setting can only be found by visiting the server
    page by navigating through the Servers > Websphere Application
    Server page.
    

Problem conclusion

  • A program defect was found which failed to pass the option in
    the page correctly. This was corrected and now all relevant
    fields are displayed in the correct settings.
    
    The fix for this APAR is currently targeted for inclusion in fix
    pack 8.5.5.13 and 9.0.0.5.  Please refer to the Recommended
    Updates page for delivery information:
    http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI85386

  • Reported component name

    WEBS APP SERV N

  • Reported component ID

    5724H8800

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-08-02

  • Closed date

    2017-08-30

  • Last modified date

    2017-08-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBS APP SERV N

  • Fixed component ID

    5724H8800

Applicable component levels

  • R900 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"900","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date:
18 October 2021