Error description

  • Environment:  IBM Sterling B2B Integrator V5.2.6.2_4 and
    SPE 9.0.0.6 *
    
    Upon analysis on the below mentioned issue, to invoke
    the business process from EDI X12 ISA envelope for Each
    document, it is observed that the DocSplit process is used to
    call the ITXA envelope.
    
    
    The sub business process configured in ISA envelope is not
    invoked and also DocSplit process ends with error due to below
    highlighted reason.
    It looks like WorkFlowId is not getting
    carry forward when the child BP is invoked.
    
    
    Below error is appearing in logs:
    
    [3814:pool-17-thread-10-state-4] [2017-06-30 10:49:09.388] ERROR
    [InvokeSIBP] SPEException executing driver.
    
    [3814:pool-17-thread-10-state-4] [2017-06-30 10:49:09.388] ERROR
    com.ibm.spe.core.exception.SPEException required parent SI
    WorkFlowId object is not present
    
    keywords: spe transformation workflow id exception invoking sub
    process bp
    

Local fix

Problem summary

  • Users Affected:
    All customers that use the enveloping or de-enveloping
    operations with the SPE Transformation Service to invoke a
    sub-BP.
    
    Problem Description:
    A sub-BP specified in an envelope to be triggered as child
    process by the SPE Transformation Service is not executed.
    
    Platforms Affected:
    All
    

Problem conclusion

  • Resolution Summary:
    A code fix is provided.
    
    
    Delivered In:
    5020602_5
    5020603_3
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI85309

  • Reported component name

    ITX ADV

  • Reported component ID

    5724Q2301

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-08-01

  • Closed date

    2017-09-13

  • Last modified date

    2017-11-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • ENVELOPE
    

Fix information

  • Fixed component name

    ITX ADV

  • Fixed component ID

    5724Q2301

Applicable component levels

  • R900 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDF7K","label":"IBM Transformation Extender Advanced"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]