A fix is available
APAR status
Closed as program error.
Error description
You run a CICS Transaction Gateway report in CICS Performance Analyzer and use SMFSTART / SMFSTOP times to limit the report data. You find your report still includes data outside of this time range. . Additional Symptom(s) Search Keyword(s): KIXREVGJT
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of CICS PA V5.3 and V5.4 * **************************************************************** * PROBLEM DESCRIPTION: Two problems are addressed in this * * APAR: * * 1. Some CICS PA reports include * * unwanted records when READ2EOF is * * specified. * * 2. The COLLECTIME value in Statistics * * HDB Summary report is not set to * * the correct INTERVAL. * **************************************************************** * RECOMMENDATION: . * **************************************************************** 1. When READ2EOF is specified in a command containing multiple reports, the first report includes all the correct records but subsequent reports contain records outside the SMFSTART/SMFSTOP time range. 2. Statistics HDB Summary reports with COLLECTTIME always report hour intervals regardless of the INTERVAL value specified in the report command.
Problem conclusion
1. The READ2EOF option is now correctly processed for all reports in the command ensuring that only the required records are included in the reports. 2. The Statistics HDB Summary report INTERVAL is now correctly set.
Temporary fix
Comments
APAR Information
APAR number
PI85307
Reported component name
CICS PERF ANALY
Reported component ID
5655Y2300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-08-01
Closed date
2017-08-24
Last modified date
2017-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI49787 UI49788
Modules/Macros
CPACMDMF
Fix information
Fixed component name
CICS PERF ANALY
Fixed component ID
5655Y2300
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPU4","label":"CICS Performance Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 October 2017