IBM Support

PI84963: WHEN USING FLOATING FORMS SOMETIMES AN ADDITIONAL FORM FEED AT THE START OF THE FIRST FLOATING FORM OCCURRENCE OCCURS.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • It is possible that an extra line is inserted in a print form,
    when using floating forms. This extra line was partially fixed
    by APAR PM96755 but it did not handle the case where a page feed
    was at the position.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users that have floating print forms that see additional     *
    * form feeds happening.                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * An additional form feed could happen for a floating form,    *
    * once PM96755 was installed. This previous APAR checked to    *
    * make sure the line count was correct but neglected to take   *
    * into account if the starting point for the original floating *
    * form was already aligned. If that was the case, a subsequent *
    * form feed was set, causing an addition page eject to occur.  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The software was updated to additionally check to see if the
    floating form already aligned to the start position.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI84963

  • Reported component name

    RATL BUS DEV

  • Reported component ID

    5724S5000

  • Reported release

    950

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-07-25

  • Closed date

    2019-01-18

  • Last modified date

    2019-01-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL BUS DEV

  • Fixed component ID

    5724S5000

Applicable component levels

  • R901 PSY

       UP

  • R911 PSY

       UP

  • R950 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: