A fix is available
APAR status
Closed as program error.
Error description
ABENDS0C4 IQCXJOIN after UI48513. A request for TOSI TERMINATION was done, but no XCF TOKEN was in place causing the abend. Another symptom is that an ABEND0C6 can be seen if the TOSI loadlib is not specified and the TOIPARMS XCFGROUP= parameter is not in place. In such case, QCF requests TOSI to TERMINATE, but no XCFGROUP was present as a TOSI INIT was not done prior. Additional Keywords: S0C4 S0C6 ABENDS0C6 Note: With APARs PI80791 and PI84670 applied and the TOIPARMS statement specified in the UNLOAD JCL, it is necessary that the user has the TOSI loadlib (SFOILOAD) specified in the STEPLIB DD. If not, the user may encounter an S806 ABEND stating that the module FOICPRM0 cannot be found since the TOSI loadlib is necessary for the OTMA cleanup introduced in the previously mentioned APARs. ABENDS806 ABEND806
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of QCF 3.2 * **************************************************************** * PROBLEM DESCRIPTION: During a run of the QCF UNLOAD job, * * an S0C6 abend was encountered when * * QCF tried to issue a STOP command * * against an active destination. * **************************************************************** * RECOMMENDATION: Install the APAR to receive the fix. * **************************************************************** During a run of the QCF UNLOAD job, an S0C6 abend was encountered when QCF tried to issue a STOP command against an active destination.
Problem conclusion
Install the APAR to receive the fix.
Temporary fix
Comments
APAR Information
APAR number
PI84670
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
320
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-07-18
Closed date
2017-09-28
Last modified date
2018-03-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI50679
Modules/Macros
IQCM2ENU IQCXCTRL IQCXGUN6 IQCXJOIN IQCXRPF0 IQCXRP61 IQCXSVF0 IQCXSV61
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R320 PSY UI50679
UP17/09/30 P F709 Ø
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
19 March 2018