Error description

  • If an abend occurs in module DFHRSSR with the following
    combination,
    CPSM 5.3 & CICS 5.2
    CPSM 5.4 & CICS 5.2
    CPSM 5.4 & CICS 5.3
    the EYUXL09xx abend summary records may not be correct.
    .
    .
    .
    Additional Symptom(s) Search Keyword(s): KIXREVCTC
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V5R3M0 and V5R4M0 Users      *
    ****************************************************************
    * PROBLEM DESCRIPTION: If an abend occurs in module DFHRSSR in *
    *                      a MAS, then the EYUXL09xx abend summary *
    *                      records may not be correct.             *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all MASes must be restarted. Note      *
    *                 that the restarts do not need to occur at    *
    *                 the same time.                               *
    ****************************************************************
    When an abend occurs in a MAS in module DFHRSSR, then module
    EYU9XLRS is called during recovery.  If the MAS is running a
    higher release of CPSM than CICS, for example if the CPSM
    release is CTS 5.3 but the CICS release is CTS 5.2, then
    EYU9XLRS is supposed to transfer control to a module
    specifically for that release of CICS.  A logic error in
    EYU9XLRS causes EYU9XLRS to always process the request itself.
    As a result, if the CPSM release is higher than the CICS
    release, the control block mappings may be incorrect and the
    resulting EYUXL09xx messages displayed may be incorrect.
    

Problem conclusion

  • Module EYU9XLRS has been updated to correct the logic error.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI84456

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    00M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-07-13

  • Closed date

    2018-02-12

  • Last modified date

    2018-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI53789 UI53790

Modules/Macros

  • CJC9XLRS CJD9XLRS CJE9XLRS CJF9XLRS CJG9XLRS EYU9XLRS
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R00M PSY UI53789

       UP18/02/15 P F802

  • R10M PSY UI53790

       UP18/02/15 P F802

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"","label":""}}]