A fix is available
APAR status
Closed as program error.
Error description
This APAR fixes the problem that IMS command authorization checking is not effective on TOSI when one of the following conditions has been met. - User runs an ORF job. - RCLASS= parameter in DFSPBxxx member is configured except IMS.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Tools Online System in * * IBM Tools Base V1.5 (FMID=HAHN150). * **************************************************************** * PROBLEM DESCRIPTION: IMS command authorization checking * * isn't effective for TOSI requests even * * if RACFCHK=Y and RCLASS= parameters are * * configured properly. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** TOSI should check whether a caller job have sufficient authority to run IMS commands when RACFCHK=Y is configured. However, it wasn't effective properly for ORF jobs. Also, RCLASS= parameter which specifies an identifier for RACF resource classes for IMS hadn't been applied for IMS command authorization checking on TOSI.
Problem conclusion
The following TOSI client modules have been changed to fix the above problem: - FOICCON0, FOICIVP0, FOICQGR0, FOICRBU0, FOICREQ0, FOICRSP0 - FOICSAFI
Temporary fix
Comments
APAR Information
APAR number
PI84060
Reported component name
TOOLS BASE
Reported component ID
5655V9300
Reported release
150
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-07-06
Closed date
2017-09-27
Last modified date
2017-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI50677
Modules/Macros
FOICCON0 FOICIVP0 FOICQGR0 FOICRBU0 FOICREQ0 FOICRSP0 FOICSAFI HAHN150J
Fix information
Fixed component name
TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R150 PSY UI50677
UP17/10/03 P F710
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.