APAR status
Closed as unreproducible in next release.
Error description
Defining an API with the following form: GET: /url/{value} where the path parameter value is mapped to an input message field of more than 10 digits causes the following message to be returned: Error 400: BAQR7019E: The parameter value could not be converted into the correct number format. This is related to the size of the number. If value is less than 10 digits, there is no msgBAQR7019E error. Additional Search words: BAQR7019 msgBAQR7019 java.lang.NumberFormatException
Local fix
Put the value into the JSON payload of the request
Problem summary
**************************************************************** * USERS AFFECTED: All users of z/OS Connect EE V3 * **************************************************************** * PROBLEM DESCRIPTION: Message BAQR7019E is returned when a * * value longer than 10 digits is * * specified. * **************************************************************** z/OS Connect EE did not convert a value longer than 10 digits into the correct numerical format and issued the BAQR7019E message.
Problem conclusion
Temporary fix
Comments
z/OS Connect EE has been changed to handle large decimal values correctly. The fix for this APAR will be delivered by the PTF for APAR PI85054.
APAR Information
APAR number
PI83974
Reported component name
Z/OS CONNECT EE
Reported component ID
5655CE300
Reported release
000
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-07-04
Closed date
2017-09-20
Last modified date
2017-09-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
Z/OS CONNECT EE
Fixed component ID
5655CE300
Applicable component levels
R000 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSNPJM","label":"IBM z\/OS Connect"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
14 February 2023