APAR status
Closed as program error.
Error description
ABENDS0C4-04 in GJEIEVTD-CRECMD
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Sysplex manager. * **************************************************************** * PROBLEM DESCRIPTION: ABENDS0C4 out of SM module GJEIEVTD * * CRECMD (GJEIEVTx and 'D' for IMS V13) * * that is followed by the other ABEND0C4 * * in DFSSPM40. * **************************************************************** * RECOMMENDATION: * **************************************************************** When a zero length message to indicate the last entry for a single-segment message is sent to SM Type-1 AO exit routine twice in a row, SM creates an improper AWE whose length in the data portion is zero. Then, the AWE is passed to SM Event Handler included in IMS control region. Since SM Event Handler does not validate the length of the data portion in the AWE, the garbage data is assumed to be length which is used to copy the data portion into the storage area owned by SM. This can cause the ABENDS0C4 due to destroying the storage area owned by IMS control region.
Problem conclusion
Install the APAR to avoid IMS abend when Sysplex Manager is started in the control region and zero length message is sent to SM Type-1 AO exit routine twice in a row.
Temporary fix
Comments
APAR Information
APAR number
PI83302
Reported component name
IMS SYSPLEX MGR
Reported component ID
5655P0100
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-06-19
Closed date
2018-05-11
Last modified date
2018-06-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI55779
Modules/Macros
GJEAOE0C GJEAOE0D GJEAOE0E GJEAOE0F GJEIAOEC GJEIAOED GJEIAOEE GJEIAOEF GJEIEVTC GJEIEVTD GJEIEVTE GJEIEVTF GJEPREQC GJEPREQD GJEPREQE GJEPREQF
Fix information
Fixed component name
IMS SYSPLEX MGR
Fixed component ID
5655P0100
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8AA","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.0"}]
Document Information
Modified date:
24 June 2022