Error description

  • This APAR resolves some issues present in z/OS Connect EE
    V3.0.0.0
    
    Additional search words: msgBAQB0007E BAQB0007 msgBAQB0007
    msgCWWKG0083W CWWKG0083 msgCWWKG0083 msgBAQR0000I BAQR0000
    msgBAQR0000
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of z/OS Connect EE V3              *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR provides fixes for multiple   *
    *                      problems.                               *
    ****************************************************************
    This APAR resolves the following problems in z/OS Connect EE
    V3:
    - A NullPointerException is reported in
      com.ibm.zosconnect.WVDataXformImpl.getJSONForBytes
      (WVDataXformImpl.java)
    - Build toolkit properties for the CICS service provider
      specifying empty values are not verified. This results in
      message:
      BAQB0007E: Error with property language. Reason:
                 Unsupported Language
      and/or incomplete SARs
    - Using nameTruncation=right leads to error message:
      BAQB0007E: Error with property nameTruncation. Reason:
                 Unsupported value
    - The interface rename functionality is not applied correctly
      for containers in a CICS Channel project
    - Required containers are not reflected in JSON schema
    - Schemas getRequestSchema and getResponseSchema are not
      returned when IMS service provider SARs are installed
    - The interactionTimeout and imsConnectTime behavior at V3
      should be the same as the behavior at V2
    - Containers not specified in the JSON schema are returned to
      the application
    - A missing responseSchema property is not correctly
      identified when using the build toolkit
    - The default IMS template results in messages CWWKG0011W
      and CWWKG0083W on start-up, because the default port number
      is not valid
    - "action=stop" for IMS service provider service results in
      an IMSGatewayException
    - The CICS channel feature is not enabled for CICS service
      provider local connections causing a
      NoClassDefFoundException when the local connection is
      initialized
    - A blank line in sample job BAQGETSJ prevents successful
      compilation
    - The template sampleCicsIpicCatalogManager does not contain
      valid SAR files
    - A SAR installed IMS service results in a
      NullPointerException when invoked
    - The IMS service provider does not use the maximum size of
      the data structure when OCCURS DEPENDING ON is present
    - Request and response structures generated by the
      build toolkit for CICS service provider are not saved
    

Problem conclusion

  • Applying the PTF for this APAR will change the reported z/OS
    Connect EE level to V3.0.0.1 as reported in the log:
    BAQR0000I: z/OS Connect Enterprise Edition version 3.0.0.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI82985

  • Reported component name

    Z/OS CONNECT EE

  • Reported component ID

    5655CE300

  • Reported release

    000

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-06-13

  • Closed date

    2017-06-22

  • Last modified date

    2017-07-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI48211 UI48212

Modules/Macros

  • BAQ00002 BAQ00126 BAQ00130 BAQ00142 BAQ00146 BAQ00147 BAQ00148
    BAQ00149 BAQ00150 BAQ00151 BAQ00158 BAQ00159 BAQ00161 BAQ00163
    BAQ00164 BAQ00165 BAQ00167 BAQ00168 BAQ00169 BAQ00171 BAQ00172
    BAQ00196 BAQ00215 BAQ00220 BAQ00221 BAQ00222 BAQ00253 BAQCAPPP
    BAQCICS  BAQDIRSH BAQGETS  BAQGETSJ BAQLDSP  BAQLDSPC BAQLDSPJ
    BAQMKDIR BAQRINFO BAQRINFP BAQSETS  BAQSETSJ BAQWEBT  BAQWLPAX
    BAQZANGL
    

Fix information

  • Fixed component name

    Z/OS CONNECT EE

  • Fixed component ID

    5655CE300

Applicable component levels

  • R000 PSY UI48211

       UP17/06/24 P F706 ¢

  • R002 PSY UI48212

       UP17/06/24 P F706 ¢

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSNPJM","label":"IBM z\/OS Connect"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]