A fix is available
APAR status
Closed as program error.
Error description
DBD/PSB/ACB Reversal decodes RMNAME for DEDB with wrong parenthesis when RMNAME length is less than 8 bytes.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for z/OS, * * Version 2 Release 2 (FMID=H27P220) users * * who use the DBD/PSB/ACB Reversal utility. * **************************************************************** * PROBLEM DESCRIPTION: DBD/PSB/ACB Reversal decodes RMNAME for * * DEDB with wrong parenthesis when RMNAME * * length is less than 8 bytes. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR fixes DBD/PSB/ACB Reversal to decode the position of parentheses correctly even if RMNAME for DEDB is less than 8 bytes character. The cause of the problem is DBD/PSB/ACB Reversal assumes RMNAME for DEDB is 8 bytes character. So the utility decodes the position of the parenthesis incorrectly if the RMNAME is less than 8 bytes character. DBD/PSB/ACB Reversal is fixed to treat RMNAME as 1-8 bytes character.
Problem conclusion
The following module has been changed to fix the above problem: FABNDEDB
Temporary fix
Comments
APAR Information
APAR number
PI82960
Reported component name
IMS LIBR INTEG
Reported component ID
5655I4200
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-06-13
Closed date
2017-07-03
Last modified date
2017-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI48510
Modules/Macros
FABNDEDB
Fix information
Fixed component name
IMS LIBR INTEG
Fixed component ID
5655I4200
Applicable component levels
R220 PSY UI48510
UP17/07/06 P F707
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]
Document Information
Modified date: