A fix is available
APAR status
Closed as program error.
Error description
The symptoms for this are the following. When starting QMF/CICS with the trace option, for example: QMFE T=ALL QMF tracing will end after the following trace entry: 'DSQCSETS:DXEDLV BEFORE SETTING VARS in MPC23_DLV'. The DXEDLV control block will contain both DXEDLV and part of DXEFBA. The second symptom is that no QMF tracing will occur when trace is initiated with the SET PROFILE (TRACE=ALL command under QMF/CICS.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All QMF for TSO/CICS V12.1 users. * **************************************************************** * PROBLEM DESCRIPTION: When QMF/CICS is started with the * * TRACE=ALL startup parameter, tracing * * will begin and terminate itself after * * the following trace entry: * * DSQCSETS:DXEDLV BEFORE SETTING VARS in * * MPC23_DLV If QMF/CICS is started and * * the trace is started from the QMF * * command line ex: SET PROFILE * * (TRACE=ALL), the trace will not start * * at all. * **************************************************************** * RECOMMENDATION: * **************************************************************** Code added in PI73765 inadvertently caused issues with the DXEDLV control block which caused issues with tracing.
Problem conclusion
This problem has been corrected.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PI82196
Reported component name
QMF-QUERY MGMT
Reported component ID
566872101
Reported release
C10
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-05-25
Closed date
2017-05-30
Last modified date
2017-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI47645
Modules/Macros
DSQCBST DSQCCI DSQCGVSI DSQCPARM DSQCSAM0 DSQCSETS DSQCSIDC DSQDGSET DSQDGSUB DSQGDE
Fix information
Fixed component name
QMF-QUERY MGMT
Fixed component ID
566872101
Applicable component levels
RC10 PSY UI47645
UP17/05/31 P F705 «
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCWRCK","label":"QMF for TSO\/CICS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"12.1.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: