Error description

  • KEYWORDS:  0c7 abend0c7 FPEUFUD2 rectrace report IFCID22 smf
    IFCID 22
    .
    Customer receives abend0C7 when processing IFCID 22 SMF records:
    .
    SYSTEM COMPLETION CODE=0C7  REASON CODE=00000000
     TIME=15.57.24  SEQ=60817  CPU=0000  ASID=013D
     PSW AT TIME OF ERROR  078D2000   80061544  ILC 4  INTC 07
       ACTIVE LOAD MODULE           ADDRESS=00007000
       NAME=FPEUFUD2
       DATA AT PSW  0006153E - BA674FA0  B6D750A0  B4C3D207
       AR/GR 0: 000000C0/8AF3B382   1: 00000000/22BDFAB8
             2: 00000000/230420A6   3: 00000000/00061FBA
             4: 00000000/0006287A   5: 00000000/22BDF99D
             6: 00000000/23042000   7: 00000000/00007000
             8: 00000000/230420A6   9: 00000000/00007000
             A: 00000000/000087BC   B: 00000000/00061E09
             C: 00000000/80060E0A   D: 00000000/00061EE0
             E: 00000000/8006151A   F: 00000000/000614D2
     END OF SYMPTOM DUMP
    IEF450I SIDDAGOS OMEGDB2 - ABEND=S0C7 U0000 REASON=000614D2  916
    TIME=15.57.24
    .
    Dump shows:
    .
                     *  *  *  DIAGNOSTIC DATA REPORT  *  *  *
    .
    .
    SEARCH ARGUMENT ABSTRACT
    
      RIDS/FPEUFUD2#L RIDS/#UNKNOWN AB/S00C7 PRCS/00000000
    REGS/0F072 REGS/0E02A
    
      Symptom               Description
      -------------------------------------
    --------------------------
      RIDS/FPEUFUD2#L      Load module name: FPEUFUD2
      RIDS/#UNKNOWN        Csect name: #UNKNOWN
      AB/S00C7             System abend code: 00C7
      PRCS/00000000        Abend reason code: 00000000
      REGS/0F072           Register/PSW difference for R0F: 072
      REGS/0E02A           Register/PSW difference for R0E: 02A
    .
    Time of Error Information
    .
      PSW: 07852000 80000000 00000000 00061544
      Instruction length: 04   Interrupt code: 0007
      Failing instruction text: BA674FA0 B6D750A0 B4C3D207
      Breaking event address: 00000000_0006198C
      Registers 0-7
      GR: 8AF3B382 22BDFAB8 230420A6 00061FBA  0006287A 22BDF99D
    23042000 00007000
      AR: 000000C0 00000000 00000000 00000000  00000000 00000000
    00000000 00000000
      Registers 8-15
      GR: 230420A6 00007000 000087BC 00061E09  80060E0A 00061EE0
    8006151A 000614D2
      AR: 00000000 00000000 00000000 00000000  00000000 00000000
    00000000 00000000  Home ASID: 001F    Primary ASID: 001F
    Secondary ASID: 001F
      PKM: 00C0          AX: 0000              EAX: 0000
    CPU STATUS:
    PSW=07852000 80000000 00000000 00061544
        (Running in PRIMARY, key 8, AMODE 31, DAT ON, PROBLEM STATE)
        Disabled for PER
       ASID(X'01BD') 061544. AREA(Subpool251Key08)+05A544 IN PRIVATE
       ASID(X'01BD') 061544. FPEUFUD2+05A544 IN PRIVATE
    .
    PSW 00061544 points to:
    .
    | FPEUFCN2 2013.178 |
    |  V520             |
    |   FMT10 HKDB520   |
    | V520 FPEUFCN2 GA  |
    | 00000 2013.178 0  |
    | 71308     x4...@  |
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2 PM                *
    *                 users of component                           *
    *                 - Batch Reporting                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: Multipart IFCID 22 records may cause    *
    *                      INCORROUT, ABEND0C7 or other            *
    *                      unpredictable results in OMPE Batch     *
    *                      RECORD TRACE / FILE.                    *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    Db2 V11 and V12 may provide incorrectly formatted multipart
    IFCID 22 records. That, in turn, may cause OMPE to encounter
    one or more problems while processing such records.
    

Problem conclusion

  • Code changed to fix this problem.
    
    It is recommended that Db2 PTF UI51544 (V12) or UI51546 (V11)
    be applied to Db2 subsystems that will have their IFCID 22
    records processed by OMPE.
    
    
    Search Keywords:
    INCORROUT BATCH RECORD TRACE FILE IFCID22 IFCID022 ABEND0C7
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI81844

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-05-18

  • Closed date

    2017-12-15

  • Last modified date

    2018-01-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI52720 UI52721 UI52722

Modules/Macros

  •    DGONFILE DGONF023 FPEUFTDS FPEUFTS2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R520 PSY UI52720

       UP17/12/19 P F712

  • R530 PSY UI52721

       UP17/12/19 P F712

  • R540 PSY UI52722

       UP17/12/19 P F712

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: