IBM Support

PI81093: ABENDS806 IN IRTFSC15 DUE TO USERMOD IRT151B IN PTF UI45466 CONTAINING A TYPO

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND806 IRTFSC15 due to usermod IRT151B in PTF UI45466
    containing the following typo:
    INCLUDE AIRTLOAD(IRTFSC15)
    ENTRY IRTFSC00
    NAME IRTFSC14(R) <------------  should be: NAME IRTFSC15(R)
    

Local fix

  • Make the above corrections to update SMPE and restart the
    system.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Program Restart Facility V2R2   *
    *                 who are using PRF in an IMS V15 QPP          *
    *                 environment and are using USERMOD IRT151B to *
    *                 copy PRF modules into SDFSRESL.              *
    ****************************************************************
    * PROBLEM DESCRIPTION: When using the IRT151B USERMOD to copy  *
    *                      PRF load modules into SDFSRESL in an    *
    *                      IMS V15 QPP environment, for the        *
    *                      purposes of running PRF out of SDFSRESL *
    *                      instead of SIRTLOAD, PRF-controlled     *
    *                      jobs will abend with a S806 abend       *
    *                      because module IRTFSC15 is missing.     *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF that corrects this APAR.       *
    ****************************************************************
    The IRT151B USERMOD uses SMPE to copy the PRF load modules into
    SDFSRESL. To perform this copy, JCLIN is used to generate link
    instructions for SMPE. The JCLIN for IRTFSC15 inadvertently
    named the module IRTFSC14 instead of IRTFSC15. This means that a
    module named IRTFSC15 is not created in SDFSRESL. Note that
    while this also means that module IRTFSC14 is incorrect, this
    should not be an issue. The IRTFSCxx modules are IMS version-
    dependent, with the last two digits of the module name
    indicating the IMS version the module is supposed to support.
    Since the correct USERMOD to support IMS V14 is the IRT141B
    USERMOD, and that USERMOD is correct, the invalid IRTFSC14
    module should never be executed.
    

Problem conclusion

  • Upon application of this PTF, and upon re-installing the new
    version of the IRT151B USERMOD, PRF-controlled jobs will no
    longer experience the ABENDS806 due to a missing IRTFSC15
    module.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI81093

  • Reported component name

    IMS PGM RESTART

  • Reported component ID

    5655E1400

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-05-04

  • Closed date

    2017-05-19

  • Last modified date

    2017-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI47383

Modules/Macros

  • IRT151B
    

Fix information

  • Fixed component name

    IMS PGM RESTART

  • Fixed component ID

    5655E1400

Applicable component levels

  • R220 PSY UI47383

       UP17/05/24 P F705

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: