APAR status
Closed as program error.
Error description
In IBM Developer for z Systems V14.0.0.3, when comparing two files with the "Compare With" > "Each Other" operation, the files cannot edited if Manage Sequence Numbers. As result, edit doesn't work and an Java stack exception appears in the workspace .log !ENTRY org.eclipse.ui 4 0 2017-03-08 11:35:27.741 !MESSAGE Unhandled event loop exception !STACK 0 java.lang.NullPointerException at com.ibm.systemz.common.jface.editor.SequenceNumberAutoEditStrate gy.customizeDocumentCommand(SequenceNumberAutoEditStrategy.java: 203) at org.eclipse.jface.text.TextViewer.customizeDocumentCommand(TextV iewer.java:3774) at org.eclipse.jface.text.TextViewer.handleVerifyEvent(TextViewer.j ava:3811) at org.eclipse.jface.text.TextViewer$TextVerifyListener.verifyText( TextViewer.java:436) at org.eclipse.swt.widgets.TypedListener.handleEvent(TypedListener. java:273) at org.eclipse.swt.widgets.EventTable.sendEvent(EventTable.java:84) at org.eclipse.swt.widgets.Display.sendEvent(Display.java:4353) at org.eclipse.swt.widgets.Widget.sendEvent(Widget.java:1061) Steps to Reproduce: - Enable Manage Sequence Numbers Cobol > Editor > Sequence Numbers > Manage Sequence Numbers - Select two modules in the z/OS Projects view - Right click and choose Compare With > Each Other - Try to modify the left or right version
Local fix
- To workaround the issue, the user can disable the preference for "Manage Sequence Numbers"
Problem summary
When in the Comparison Ciew, if "Manage Sequence Numbers" was enabled, the file could not be edited.
Problem conclusion
The files can be edited in comparison view with "Manage Sequence Numbers" enabled.
Temporary fix
Comments
APAR Information
APAR number
PI80929
Reported component name
DEV FOR Z SYS
Reported component ID
5724T0700
Reported release
301
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-05-03
Closed date
2018-01-24
Last modified date
2018-01-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
EXP FOR Z/OS CL
Fixed component ID
5655EXP00
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSBDYH","label":"IBM Explorer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"301","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
24 January 2018