IBM Support

PI80782: INTERNAL CODE CLEAN UP. CODE HAS BEEN ALTERED TO ADDRESS INTERNAL ABENDS FOUND IN THE INTERNAL DIAG TABLE.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Internal code clean up. Code has been altered to address
    internal abends found in the internal Diag Table.
    

Local fix

  • Add PARALLEL(N) to the CQMPARMS/ADHPARMS parameter file
    (recycle the Query Monitor and Guardium STAP collectors
    to pick up the change).
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Common Collector                *
    ****************************************************************
    * PROBLEM DESCRIPTION: Internal code clean up. Code has        *
    *                      been altered to address internal        *
    *                      abends found in the internal Diag       *
    *                      Table.                                  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Code has been changed to fix this problem
    

Problem conclusion

  • APPLY the PTF
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI80782

  • Reported component name

    COMMON COLLECTO

  • Reported component ID

    5639OLC00

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-04-28

  • Closed date

    2017-05-30

  • Last modified date

    2017-07-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI47646

Modules/Macros

  •    CQCMALOX CQCMHSTV CQCMPRA1 CQCMPRB1 CQCMPRC5
    CQCMSCLN CQCMSTRM
    

Fix information

  • Fixed component name

    COMMON COLLECTO

  • Fixed component ID

    5639OLC00

Applicable component levels

  • R110 PSY UI47646

       UP17/06/13 P F706

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.