A fix is available
APAR status
Closed as program error.
Error description
The CICS preprocessor does not accept a double quote embedded within 2 single quotes as a valid literal and error DFH7035I is given ie: DFH7035I C 02606 CONTINUATION AND TWO QUOTES ASSUMED. A NON-NUMERIC LITERAL WAS BEING CONTINUED.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * CICS XML users * **************************************************************** * PROBLEM DESCRIPTION: * * A CICS preprocessor error can occur when using XML support * * complaining about quotes being incorrect. * * The generated cobol was generating adouble quote within 2 * * single quotes ('"'), but the cics preprocessor doesn't like * * that. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The logic was changed to generate """" instead of '"'. This allows the cics preprocessor to work correctly.
Temporary fix
Comments
APAR Information
APAR number
PI80588
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-04-26
Closed date
2019-01-21
Last modified date
2019-01-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R950 PSY
UP
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950"}]