Error description

  • HP Unload gets ABEND878 reason code=14 when all the following
    conditions are met:
     - APAR PI77214 is applied
     - Non-HALDB OSAM data set contains no segment (empty)
     - RANSIZE control statement is not specified
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS High Performance Unload for *
    *                 z/OS Version 1 Release 2 (FMID=H1IN120)      *
    ****************************************************************
    * PROBLEM DESCRIPTION: The HSSR engine of HP Unload gets       *
    *                      ABEND878 reason code=14.                *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    The HSSR engine of HP Unload gets ABEND878 reason code=14 when
    all the following conditions are met:
    - APAR PI77214 is applied
    - Non-HALDB OSAM data set contains no segment (empty)
    - RANSIZE control statement is not specified
    The HSSR engine of HP Unload attempts to obtain the internal
    control block. But, a calculation of the control block size is
    incorrectly.
    

Problem conclusion

  • The HSSR engine of HP Unload has been modified to calculate the
    control block size correctly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI79973

  • Reported component name

    IMS HIGHPERF UN

  • Reported component ID

    5655E0600

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-04-13

  • Closed date

    2017-04-19

  • Last modified date

    2017-05-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI46525

Modules/Macros

  •    FABH512
    

Fix information

  • Fixed component name

    IMS HIGHPERF UN

  • Fixed component ID

    5655E0600

Applicable component levels

  • R120 PSY UI46525

       UP17/04/21 P F704

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX89K","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]

Document Information

Modified date:
14 December 2020