IBM Support

PI79297: VARIOUS FIXES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This APAR includes the following fixes:
    1. The following errors occur on a load when using a CCSID that
      uses a double byte character for double quotes:
      AQT10301I  An error occurred in the SYSPROC.DSNUTILU service
      of your database management system (DBMS).
        HLOU5724E The ACCEL_LOAD_TABLES stored procedure has failed.
    2. The following error occurs when the load statement is very
      large, for example, when many partitions are loaded in the
      same step:
        HLOP9901E Input buffer size is too small.
    .
    3. When using the backup function to copy a AOT table, column
       JOBTYPE in HLOUCOPY incorrectly contains a value of 'L'
       instead of 'B'.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM DB2 Analytics Accelerator       *
    *                 Loader for z/OS.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR includes the following fixes: *
    *                      1. The following errors occur on a load *
    *                       when using a CCSID that uses a double  *
    *                       byte character for double quotes:      *
    *                        AQT10301I  An error occurred in the   *
    *                         SYSPROC.DSNUTILU service of your     *
    *                         database management system (DBMS).   *
    *                        HLOU5724E The ACCEL_LOAD_TABLES       *
    *                         stored procedure has failed.         *
    *                      2. The following error occurs when the  *
    *                       load statement is very large, for      *
    *                       example, when many partitions are      *
    *                       loaded in the same step:               *
    *                          HLOP9901E Input buffer size is too  *
    *                           small.                             *
    *                      3. When using the backup function to    *
    *                       copy a AOT table, column JOBTYPE in    *
    *                       HLOUCOPY incorrectly contains a value  *
    *                       of 'L' instead of 'B'.                 *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI79297

  • Reported component name

    IDAA LOADER ZOS

  • Reported component ID

    5639OLA00

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-04-03

  • Closed date

    2017-05-09

  • Last modified date

    2017-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    HLOGDYNA
    

Fix information

  • Fixed component name

    IDAA LOADER ZOS

  • Fixed component ID

    5639OLA00

Applicable component levels

  • R210 PSY UI47120

       UP17/05/19 P F705

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSKRKK","label":"IBM Db2 Analytics Accelerator Loader for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]