A fix is available
APAR status
Closed as program error.
Error description
KEY WORDS: U2008 KO2ZTOPB OB0933 00001528 KO2OINTB 040007D8 LROWS This issue is caused when the collector has more lines of data to display than the logical size of the screen. The logical size of the screen is controlled by the LROWS parameter in the RKD2PAR(RVTMnnnn) member(s). The value of LROWS is set by the PARMGEN variable KD2_CLASSIC_LROWS . V530 Customer is receiving the following abend in the OMPE Server/Collector STC; . IEA794I SVC DUMP HAS CAPTURED: 849 DUMPID=024 REQUESTED BY JOB (PAJ6OMEG) DUMP TITLE=OMEGAMON II FOR DB2: COMPID=5655OPE00, JOB=PAJ6OMEG, LMOD=KO2ZTOPB#L, CSECT=#UNKNOWN, OFFSET=012916 OMEGAMON: OB0933 OMEGAMON resource cleanup initiated for abend U2008 RC OMEGAMON: OB0935 OMEGAMON resource cleanup complete CI0970: OMEGAMON SUBTASK ABEND CODE=040007D8 PSW=077D10009B61370E TCB= CI0971: PROGRAM NAME=KO2OINTB . DUMP SHOWS: . * * * DIAGNOSTIC DATA REPORT * * * . SEARCH ARGUMENT ABSTRACT . RIDS/KO2ZTOPB#L RIDS/#UNKNOWN AB/U2008 PRCS/00001528 . Symptom Description --------------------- ------------------------ RIDS/KO2ZTOPB#L Load module name: KO2ZTOPB RIDS/#UNKNOWN Csect name: #UNKNOWN AB/U2008 User Abend code: 2008 PRCS/00001528 Abend reason code: 00001528 . Time of Error Information . PSW: 07751000 80000000 00000000 1B61370E Instruction length: 02 Interrupt code: 000D Failing instruction text: 00181610 0A0D0000 5CC4E4D4 . Breaking event address: 00000000_00000000 . AR/GR 0-1 00000000/00000000_84000000 00000000/00000000_840007D8 AR/GR 2-3 00000000/00000000_00001528 00000000/00000000_7E90B340 AR/GR 4-5 00000000/00000000_01708E60 00000000/00000000_1D36F088 AR/GR 6-7 00000000/00000000_1D9BC0F0 00000000/00000000_1D96C2B0 AR/GR 8-9 00000000/00000000_1D36F000 00000000/00000000_1D36EBC0 AR/GR10-11 00000000/00000000_1C8691DC 00000000/00000000_7F084078 AR/GR12-13 00000000/00000000_1D9FDFC0 00000000/00000000_1D7D16B8 AR/GR14-15 00000000/9C8691FE_1D369000 00000000/00000000_00001528 . PSW 1B61370E points to: . | OMVTEND .....00* | | OMPEZTK OMPE V | | 530 N/A 03/20 | | /15 17.52 HKDB53 | | 0 Copyright (C) | | IBM Corp. 1987, | | 2014............ | .
Local fix
Increase LROWS In PARMGEN reference variable KD2_CLASSIC_LROWS LROWS minumum value is 99 and the maximum value is 9999 or you may manually edit hilev.RKD2PAR(RVTMnnnn) and increase the value of LROWS. However this change will be lost when the PARMGEN process is rerun due to an SMPE Action Hold.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM users of * * component - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: OB0933 OMEGAMON RESOURCE CLEANUP * * INITIATED FOR ABEND U2008 RC=00001528 * * IN LMOD=KO2ZTOPB#L, CSECT=#UNKNOWN. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Abend U2008 RC=00001528 in OMPEZTK happened because the allocated stacks were not released during THDW command execution when inactive thread display exceeds LROWS setting.
Problem conclusion
Change logic to prevent the abend. Keywords U2008 KO2ZTOPB 00001528 THDW
Temporary fix
Comments
APAR Information
APAR number
PI78063
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-03-13
Closed date
2017-08-03
Last modified date
2017-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI49304 UI49303
Modules/Macros
KO2APCCA KO2APCCK KO2APCCS KO2APCC2 KO2APC1A KO2APC1K KO2APC1S KO2APC12 KO2APC2A KO2APC2K KO2APC2S KO2APC22 KO2APC3A KO2APC3K KO2APC3S KO2APC32 KO2APC4A KO2APC4K KO2APC4S KO2APC42 KO2CDFCA KO2CDFCK KO2CDFCS KO2CDFC2 KO2CIFDB KO2CT2SA KO2CT2SK KO2CT2SS KO2CT2S2 KO2ODSTB KO2OTHJB KO2OTHKB KO2OTHMB KO2OTHNB KO2OTHOB KO2OTHPB KO2OTHQB KO2OTHRB KO2OTHSB KO2OTHTB KO2OTHUB KO2OTHVB KO2OTHWB KO2OTHXB KO2OTHYB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 September 2017