Error description

  • If the STAP Collector (V9.1 or V10.0) is started first after an
    IPL and is monitoring a DB2 subsystem, CQM may not collect data
    if it is monitoring the same DB2 and was started after STAP,
    with the OPTKEY(CORRNAME) setting on.
    

Local fix

  • 1. Stop CQM and STAP.
    2. Start CQM first, followed by STAP.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM DB2 Query Monitor z/OS.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: If the STAP Collector (V9.1 or V10.0)   *
    *                      is started first after an IPL and is    *
    *                      monitoring a DB2 subsystem, CQM may not *
    *                      collect data if it is monitoring the    *
    *                      same DB2 and was started after STAP,    *
    *                      with the OPTKEY(CORRNAME) setting on.   *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI76644

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    330

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-02-14

  • Closed date

    2017-04-12

  • Last modified date

    2017-05-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI46388

Modules/Macros

  • CQM#SSMN
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R330 PSY UI46388

       UP17/04/18 P F704

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.