Error description

  • Session Listener requires to be registered explicitly in
    application to avoid memory leak so this fix registers it out
    of the box in portlet bridge
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of the IBM WebSphere Application  *
    *                  Server JSF portlet bridge feature           *
    ****************************************************************
    * PROBLEM DESCRIPTION: A memory leak was occuring during test  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    A memory leak was occuring due to portlet session beans not
    being destroyed properly.
    

Problem conclusion

  • To correct this, a session listener had to be registered in
    such a way that existing JSF portlet bridge applications would
    not have to change their configuration.
    
    This has been accomplished with this fix.
    
    The fix for this APAR is currently targeted for inclusion in
    fix pack 9.0.0.3.  Please refer to the Recommended Updates
    page for delivery information:
    http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI75876

  • Reported component name

    WEBSPHERE APP S

  • Reported component ID

    5724J0800

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-02-03

  • Closed date

    2017-03-07

  • Last modified date

    2017-12-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE APP S

  • Fixed component ID

    5724J0800

Applicable component levels

  • R900 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
03 May 2022