IBM Support

PI75622: ENHANCEMENT TO AUTOMATICALLY SET A COMMON TO_LOGPOINT FOR MULTIPLE OBJECTS.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • This enhancement allows DB2 Cloning Tool Table Space Cloning to
    generate TO-LOGPOINT synchronization batch JCL jobs for the
    selected table space clone profiles.  The synchronization jobs
    allow objects that are spread over multiple profiles to be
    cloned to the same log point.  If the selected table space clone
    profiles have different source SSIDs, DB2 Cloning Tool Table
    Space Cloning generates one TO-LOGPOINT synchronization job for
    each source SSID.
    .
    The generated table space cloning jobs and TO-LOGPOINT
    synchronization batch JCL jobs should be submitted in the
    following order:
      1) Run the Source JCL jobs sequentially.
      2) Run the TO-LOGPOINT synchronization JCL jobs;
      3) Run the Target JCL jobs sequentially.
    .
    The same value of TO-LOGPOINT in all of the JCL jobs guarantees
    the consistency of data on the target subsystem after cloning.
    This enhancement can be used only when DATA-MOVER PGM is
    ADRDSSU, EMCAPI, or NONE, and LA-ENABLE is set to YES.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM DB2 Cloning Tool z/OS.          *
    ****************************************************************
    * PROBLEM DESCRIPTION: The generated table space cloning jobs  *
    *                      and TO-LOGPOINT synchronization batch   *
    *                      JCL jobs should be submitted in the     *
    *                      following order:                        *
    *                      1. Run the Source JCL jobs              *
    *                       sequentially.                          *
    *                      2. Run the TO-LOGPOINT synchronization  *
    *                       JCL jobs;                              *
    *                      3. Run the Target JCL jobs              *
    *                       sequentially.                          *
    *                      The same value of TO-LOGPOINT in all    *
    *                      of the JCL jobs guarantees the          *
    *                      consistency of data on the target       *
    *                      subsystem after cloning. This           *
    *                      enhancement can be used only when       *
    *                      DATA-MOVER PGM is ADRDSSU, EMCAPI, or   *
    *                      NONE, and LA-ENABLE is set to YES.      *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

Temporary fix

Comments

  • APPLY the PTF.
    

APAR Information

  • APAR number

    PI75622

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    320

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-01-27

  • Closed date

    2017-02-15

  • Last modified date

    2017-03-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI44713

Modules/Macros

  •    CKZ#CARD CKZ#CNTL CKZ#LGAC CKZ#MAIN CKZ#RUNT
    CKZ#SYSC CKZEXUTL CKZHBLSJ CKZHDSML CKZHDTCL CKZHELAP CKZHNPPR
    CKZHPLAP CKZHULAP CKZHWLSJ CKZH489I CKZIMUTL CKZUMEPL CKZUSYNC
    CKZ00501 CKZ00535 CKZ00545 CKZ1BLSJ CKZ1DTCL CKZ1ELAP CKZ1NPPR
    CKZ1PLAP CKZ1ULAP CKZ1WLSJ CKZ2ADRD CKZ2BCLC CKZ2BDCJ CKZ2BLSJ
    CKZ2CLON CKZ2CMND CKZ2CMPN CKZ2COCP CKZ2COMM CKZ2CTCP CKZ2DALV
    CKZ2DAPS CKZ2DBSS CKZ2DB2A CKZ2DCCC CKZ2DCCH CKZ2DCRN CKZ2DDAT
    CKZ2DEFD CKZ2DFIX CKZ2DREN CKZ2DRFD CKZ2DSAP CKZ2DSCJ CKZ2DSCL
    CKZ2DSCN CKZ2DSCP CKZ2DSCS CKZ2DSQL CKZ2DSTP CKZ2DTCP CKZ2DTCS
    CKZ2EDAC CKZ2EDCV CKZ2EDDF CKZ2EDDL CKZ2EDDS CKZ2ELDC CKZ2EMCS
    CKZ2EMDC CKZ2ESCP CKZ2ETCP CKZ2FTSJ CKZ2GFSJ CKZ2GVAR CKZ2IVPL
    CKZ2JSKL CKZ2LACR CKZ2LAOP CKZ2LSTS CKZ2MAIN CKZ2MEPL CKZ2MSTF
    CKZ2MTMB CKZ2NPPR CKZ2OMRC CKZ2PDAC CKZ2PDBL CKZ2PJCI CKZ2PLAP
    CKZ2PLDC CKZ2PMDC CKZ2PRDM CKZ2PRFL CKZ2PRIM CKZ2PZPI CKZ2SASV
    CKZ2SBCI CKZ2SCLT CKZ2SFRJ CKZ2SFSJ CKZ2SFTJ CKZ2SIDL CKZ2SJCI
    CKZ2SJCL CKZ2SJTS CKZ2SJTV CKZ2SKL  CKZ2SOMT CKZ2SOPR CKZ2SPCC
    CKZ2SPRF CKZ2SRNM CKZ2SRSV CKZ2SSCP CKZ2SSDS CKZ2SSID CKZ2SSLB
    CKZ2SSMC CKZ2SSSC CKZ2SSSJ CKZ2SSTM CKZ2SSTN CKZ2SSTS CKZ2SSTT
    CKZ2SSTV CKZ2STSS CKZ2SUTL CKZ2TCOP CKZ2TDDC CKZ2TDDF CKZ2TDSP
    CKZ2TJCL CKZ2TRCF CKZ2TSCP CKZ2TSET CKZ2TTRN CKZ2ULCL CKZ2USET
    CKZ2VRFY CKZ2XMOD CKZ4ASYS CKZ4PROF CKZ4RDLL CKZ4TPRF CKZ48
    CKZ6ADLL CKZ6BCPR CKZ6BLST CKZ6BOCL CKZ6BPDD CKZ6BPRM CKZ6BSSC
    CKZ6BSSP CKZ6BTCL CKZ6BTSS CKZ6CCF  CKZ6DACL CKZ6DDFL CKZ6DMLS
    CKZ6EMLS CKZ6FIXC CKZ6GRPR CKZ6HLLS CKZ6HLQS CKZ6ICFL CKZ6IGNR
    CKZ6IPRM CKZ6JBCD CKZ6JTLS CKZ6LDLS CKZ6MAIN CKZ6MDLS CKZ6OMRC
    CKZ6OPDD CKZ6OTLS CKZ6PAPI CKZ6PDLS CKZ6RENM CKZ6RPDD CKZ6SCPR
    CKZ6SMSL CKZ6SPDD CKZ6SPRM CKZ6SQLC CKZ6SSMS CKZ6SSPL CKZ6SSPR
    CKZ6STGL CKZ6STPC CKZ6STRT CKZ6TCPR CKZ6TPDD CKZ6TPRM CKZ6TVLS
    CKZ6UDDS CKZ6UPDC CKZ6UXCL CKZ6VALF CKZ6VPLS CKZ6VRFY CKZ6WEMS
    CKZ7ADLL CKZ7DBCF CKZ7LAPI CKZ7MAIN CKZ7MSGS CKZ7PRMF CKZ7REV
    CKZ7STRU CKZ7SYSU CKZ8CFCR CKZ8CMDB CKZ8CMDE CKZ8CMDI CKZ8EXCB
    CKZ8LOGS CKZ8MAIN CKZ8PRSR CKZ8TOOL CKZ8UTIL HCKZ320
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R320 PSY UI44713

       UP17/03/02 P F702

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
02 March 2017