A fix is available
APAR status
Closed as program error.
Error description
When issuing the ST action from the JG (Job Group) panel, the message STAT SSI ERR 0008-0008 can appear in some cases if ST is setup to sort on a delayed field (such as RD-DAte) and there are jobs that are on the resulting ST display that do not have a JOBID because the hob has not yet been created.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of SDSF V2R2. * **************************************************************** * PROBLEM DESCRIPTION: When issuing the ST action from the JG * * (Job Group) panel, the message STAT SSI * * ERR 0008-0008 may appear for jobs in * * the job group have not been submitted * * and delayed columns are requested. * * * **************************************************************** * RECOMMENDATION: * **************************************************************** Jobs in a job group that have not been submitted are not assigned a jobid until the job enters the system. When accessing the ST panel from JG, all jobs in the job group are listed regardless of whether they have been submitted or not. If a delayed column is visible or required due to filtering or sorting, SDSF invokes the extended status SSI to obtain the data. However, for jobs with no jobid, this call will fail with message STAT SSI ERR 0008-0008.
Problem conclusion
ISFDFGT has been changed to verify a jobid is present prior to calling the extended status SSI.
Temporary fix
Comments
APAR Information
APAR number
PI75535
Reported component name
SDSF
Reported component ID
566548801
Reported release
7A0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-01-26
Closed date
2017-01-30
Last modified date
2017-03-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI44310
Modules/Macros
ISFDFGT
Fix information
Fixed component name
SDSF
Fixed component ID
566548801
Applicable component levels
R7A0 PSY UI44310
UP17/02/15 P F702
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 March 2017