A fix is available
APAR status
Closed as program error.
Error description
ABENDS0C7 FABADA5 at X'1246' when the number of IOVF CI's used by a UOW is 100000 or greater. S0C7
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of HPFPU Fast Path Advanced Tool * * and Fast Path Basic Tools in Fast Path * * Solution Pack Version 1 Release 3 (FMID: * * HAHQ130). * **************************************************************** * PROBLEM DESCRIPTION: FPB DEDB pointer checker utility gets * * ABENDS0C7 when a UOW uses 100,000 or * * more IOVF CIs. * * FPA Analyze function and FPB DEDB * * pointer checker utility get ABENDS0CB * * when a UOW contains excessive large * * number of database records. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** FPB DEDB pointer checker utility FABADA5 program gets ABENDS0C7 when a UOW uses 100,000 or more IOVF CIs. This abend is caused by a product overflow of the MP (MULTIPLY DECIMAL) instruction. FPA Analyze function and FPB DEDB pointer checker utility FABADA5 program get ABENDS0CB when a UOW contains excessive large number of database records (approximately 90,000 records). This abend occurs when a standard deviation of the physical segment I/O is calculated and is caused by a quotient overflow of the DP (DIVIDE DECIMAL) instruction.
Problem conclusion
FPB DEDB pointer checker utility is modified to increase the first operand of the MP instruction to avoid the ABENDS0C7. FPA Analyze function and FPB DEDB pointer checker utility are modified not to calculate the standard deviation of the physical segment I/O if the calculation would possibly be overflowed. In this case, ***** is set instead of a numerical value.
Temporary fix
Comments
APAR Information
APAR number
PI75264
Reported component name
IMS FP SOLUTION
Reported component ID
5655W1400
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-01-20
Closed date
2017-05-09
Last modified date
2017-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI47094
Modules/Macros
FABADA5 HFPA5SI0
Fix information
Fixed component name
IMS FP SOLUTION
Fixed component ID
5655W1400
Applicable component levels
R130 PSY UI47094
UP17/05/11 P F705
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Fast Path Solution Pack"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130"}]