IBM Support

PI74441: ABEND 0C1-1 IN MODULE FPEUFUD2 WHEN GENERATING AN AUDIT REPORT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • SYSTEM COMPLETION CODE=0C1  REASON CODE=00000001
    occurs when generating an audit report:
    TIME=13.37.48  SEQ=02545  CPU=0000  ASID=0021
    PSW AT TIME OF ERROR  078D1000   8005653A  ILC 2  INTC 01
       ACTIVE LOAD MODULE           ADDRESS=00007000
    OFFSET=0004F53A
       NAME=FPEUFUD2
       DATA AT PSW  00056534 - 000328DC  0003DB74  000404BC
       AR/GR 0: 00000000/00000A0D   1: 00000000/184FC788
             2: 00000000/000BC558   3: 00000000/00000000
             4: 000E0003/00000001   5: 00000000/00056536
             6: 00000000/184F94B8   7: 00000000/00000000
             8: 00000000/00000008   9: 00000000/800BBF66
             A: 00000000/00007000   B: 00000000/184F9887
             C: 00000000/0004C040   D: 00000000/0004C108
             E: 00000000/0004C108   F: 00000000/00046162
    END OF SYMPTOM DUMP
    occurs when generating an AUDIT report
    

Local fix

  • wait for PTF
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - Batch Reporting                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C1 encountered during OMPE Batch  *
    *                      Audit Report.                           *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    PROBLEM SUMMARY:
    SQL text in IFCID 145 exceeding 4000 bytes caused OMPE internal
    buffer overflow and code corruption followed by ABEND0C1 due to
    'wild branch'.
    
    PROBLEM CONCLUSION:
    Code changed to fix this problem.
    
    KEYWORDS:
    ABENDC01 OMPE BATCH AUDIT REPORT
    

Problem conclusion

  • Code changed to fix this problem.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI74441

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    530

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-01-05

  • Closed date

    2017-02-19

  • Last modified date

    2017-06-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI44910 UI44911 UI44912

Modules/Macros

  • FPEUFTDS FPEUFTS2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R511 PSY UI44910

       UP17/02/24 P F702

  • R520 PSY UI44911

       UP17/02/24 P F702

  • R530 PSY UI44912

       UP17/02/24 P F702

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
22 June 2017