A fix is available
APAR status
Closed as program error.
Error description
SYSTEM COMPLETION CODE=0C1 REASON CODE=00000001 occurs when generating an audit report: TIME=13.37.48 SEQ=02545 CPU=0000 ASID=0021 PSW AT TIME OF ERROR 078D1000 8005653A ILC 2 INTC 01 ACTIVE LOAD MODULE ADDRESS=00007000 OFFSET=0004F53A NAME=FPEUFUD2 DATA AT PSW 00056534 - 000328DC 0003DB74 000404BC AR/GR 0: 00000000/00000A0D 1: 00000000/184FC788 2: 00000000/000BC558 3: 00000000/00000000 4: 000E0003/00000001 5: 00000000/00056536 6: 00000000/184F94B8 7: 00000000/00000000 8: 00000000/00000008 9: 00000000/800BBF66 A: 00000000/00007000 B: 00000000/184F9887 C: 00000000/0004C040 D: 00000000/0004C108 E: 00000000/0004C108 F: 00000000/00046162 END OF SYMPTOM DUMP occurs when generating an AUDIT report
Local fix
wait for PTF
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - Batch Reporting * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C1 encountered during OMPE Batch * * Audit Report. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: SQL text in IFCID 145 exceeding 4000 bytes caused OMPE internal buffer overflow and code corruption followed by ABEND0C1 due to 'wild branch'. PROBLEM CONCLUSION: Code changed to fix this problem. KEYWORDS: ABENDC01 OMPE BATCH AUDIT REPORT
Problem conclusion
Code changed to fix this problem.
Temporary fix
Comments
APAR Information
APAR number
PI74441
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-01-05
Closed date
2017-02-19
Last modified date
2017-06-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI44910 UI44911 UI44912
Modules/Macros
FPEUFTDS FPEUFTS2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R511 PSY UI44910
UP17/02/24 P F702
R520 PSY UI44911
UP17/02/24 P F702
R530 PSY UI44912
UP17/02/24 P F702
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]