A fix is available
APAR status
Closed as program error.
Error description
SYSPARMS TRACE displays SPT01 INLINE LENGTH (SPT01_INLINE_LENGTH) with a value of 1 the SMF record for SYSPARM shows a value of x'FFFF' (-1)
Local fix
use RECTRACE TRACE LEVEL(LONG) INCLUDE(IFCID(106))
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2M Components * * Affected: Batch Reporting * **************************************************************** * PROBLEM DESCRIPTION: SYSPARMS TRACE displays * * "SPT01_INLINE_LENGTH" with a value of * * 1 in case when customer sets * * "NOINLINE" in DSNTIPA2 DB2 * * Installation panel. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** DB2 sets "-1" value for SPT01_INLINE_LENGTH in case when customer specifies "NOINLINE" for this parameter in DSNTIPA2 installation panel. SYSPARMS TRACE report should also display "-1" value instead of 1.
Problem conclusion
SYSPARMS TRACE report should display "-1" value for SPT01_INLINE_LENGTH parameter when customer sets "NOINLINE" in DSNTIPA2 DB2 installation panel. This point also should be reflected in documentation.
Temporary fix
Comments
APAR Information
APAR number
PI74256
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-12-29
Closed date
2017-06-06
Last modified date
2017-07-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PI81149 UI47818
Modules/Macros
DGOWF107 KDPHISTC
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R530 PSY UI47818
UP17/06/17 P F706
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: