A fix is available
APAR status
Closed as program error.
Error description
After DB2 sub system abended the sub-sequent re-start caused OMPE collector to abend with 0c4-10 as soon as Object Analysis (OA) started ABEND0C4-10 O2EGX1 +382, R2 contains an invalid address. OMEGAMON II FOR DB2 DUMP TASK=OBJ-DPA1,ID=EGX1 ,MOD=KO2EGX1K,OFFSET=000382,CODE=S0C4/00000010
Local fix
Run Object Analysis on an as-needed basis do not have it run at OMPE start-up
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - OA-Object Analysis * **************************************************************** * PROBLEM DESCRIPTION: DB2 crash (abend S0C4) in Object * * Analysis during DB2 indoubt recovery. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: Incorrect control block processing in Object Analysis during DB2 indoubt recovery. PROBLEM CONCLUSION: Control block processing corrected. KEYWORDS: ABEND0C4 O2EGX1 OBJECT ANALYSIS RECOVER INDOUBT
Problem conclusion
Control block processing corrected.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PI73915
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-12-16
Closed date
2017-03-13
Last modified date
2017-06-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI45521 UI45522 PI79523
Modules/Macros
KO2EGX1A KO2EGX1K KO2EGX1S KO2XTHSA KO2XTHSK KO2XTHSS KO2XTH1A KO2XTH1K KO2XTH1S KO2XTH3A KO2XTH3K KO2XTH3S KO2ZIIOA KO2ZIIOK KO2ZIIOS
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]