IBM Support

PI73405: QCF EXTENSIONS SAMPLE MEMBER IQCIMSII TO BE UPDATED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Sample member IQCIMSII to be updated to not suggest a FAIL0085
    with ACTION=WAIT as this level has caused an IMS failure due to
    a conflict with IMS taking control before QCF can trigger the
    failsafe. The new suggestion will be FAIL0075 and a WAIT, to
    avoid a rare case where an IMS ABEND0758 can occur.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Updates were made to IQCIMSII to remove *
    *                      suggested AREA/FAILSAFE cards over 75%. *
    *                      Also, IQCQSNnn members now include the  *
    *                      TOSI loadlib in the STEPLIB             *
    *                      concatenation.                          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI73405

  • Reported component name

    IMS QUEUE CNTL

  • Reported component ID

    5697E9900

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2016-12-07

  • Closed date

    2017-01-12

  • Last modified date

    2018-11-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI43869

Modules/Macros

  •    IQCIMSII IQCPRCAB IQCPRCBC IQCPRCCD IQCPRCUT
    

Fix information

  • Fixed component name

    IMS QUEUE CNTL

  • Fixed component ID

    5697E9900

Applicable component levels

  • R320 PSY UI43869

       UP17/01/18 P F701

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.