A fix is available
APAR status
Closed as new function.
Error description
Code is being added to support a future function of IMS
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 3 Release 1 (FMID=HPC2310) * * users. * **************************************************************** * PROBLEM DESCRIPTION: This APAR adds IMS V15 support to * * HPPC V3.1. * * Additionally, this APAR fixes ABEND0C4 * * in HD Tuning Aid running under IMS V14. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR enables IMS High Performance Pointer Checker to run under IMS Version 15. *** Notes *** - When you use the Integrated DB Sensor function in HD Pointer Checker on IMS Version 15 environment, you need to apply APAR PI73196 to IMS Database Reorganization Expert V4.1. - When you use IMS Library Integrity Utilities' DBD map function or DBD reversal function in HD Pointer Checker on IMS Version 15 environment, you need to apply APAR PI73057 to IMS Library Integrity Utilities V2.2. - When you monitor IMS full-function database VSAM data sets by Space Monitor or the Integrated DB Sensor function on IMS Version 15 environment, you need to apply APAR PI72067 to Tool Base V1.6. ************* KEYWORDS: IMSV15TGT/K Additionally, this APAR fixes the problem that ABEND0C4 occurs in FABTHCHG CSECT around offset X'14E2' or in a PHDAM randomizin routine when the HD Tuning Aid utility runs under IMS V14 and on of the following conditions is met: - Randomizing parameters, high key values of partitions, or partition selection for the PHDAM database are changed - New partitions are added to the PHDAM database - A database is simulated as a PHDAM database
Problem conclusion
Temporary fix
Comments
Documentation Changes: Note: The Part and Chapter numbers are those of the PDF file. The documentation is modified as follows: ================================================================ IMS High Performance Pointer Checker for z/OS, V3R1, User's Guide (SC19240103) ================================================================ >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> Part1. Introduction and product setup >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> ---------------------------------------------------------------- Chapter 1. Overview of IMS HP Pointer Checker ---------------------------------------------------------------- - IMS HP Pointer Checker terminology ---------------------------------------------------------------- <<The following description is changed:>> To make this information easier to read, the version and release levels of IMS are abbreviated, as follows: - IMS Version 13 refers to IMS Version 13 Release 1. - IMS Version 14 refers to IMS Version 14 Release 1. - IMS Version 15 refers to IMS Version 15 Release 1. ---------------------------------------------------------------- - IMS HP Pointer Checker documentation and updates - Related publications ---------------------------------------------------------------- <<The following IMS publications have been added to the table:>> Short title Order number for Version 15 ----------------------------- --------------------------- IMS Database Administration ----------------------------- --------------------------- IMS Operations and Automation ----------------------------- --------------------------- IMS System Definition ----------------------------- ---------------------------
APAR Information
APAR number
PI73056
Reported component name
IMS POINTER CHE
Reported component ID
5655E0900
Reported release
310
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2016-11-30
Closed date
2017-02-23
Last modified date
2017-03-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI44958
Modules/Macros
FABPADBS FABPDATE FABPGVT0 FABPIBLK FABPLINK FABPPSDA FABPPSIX FABPPSLF FABPPSMF FABPPUT0 FABPUCB0 FABRIMSV FABRRLDF FABRULDF FABTHCHG FABTHCRE FABTHOUT FABTROOT HPC2310J
| SC19240103 |
Fix information
Fixed component name
IMS POINTER CHE
Fixed component ID
5655E0900
Applicable component levels
R310 PSY UI44958
UP17/02/28 P F702
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 March 2017