PI72345: IEW2742S D212 OPEN FOR INPUT FAILED FOR PDSE MEMBER DSNRLI RETURN CODE 16 AND REASON CODE DC2CB000

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IEW2742S D212 OPEN FOR INPUT FAILED FOR PDSE MEMBER DSNRLI FROM
    DDNAME *LNKLST*, CONCATENATION NUMBER 118.  BINDER
             MODULE IEWBXILO ISSUED RETURN CODE  16 AND REASON CODE
    DC2CB000
    
    
    SYSTEM COMPLETION CODE=C03
    TIME=06.34.18  SEQ=28097  CPU=0000  ASID=00C8
    PSW AT TIME OF ERROR  070C0000   86371140  ILC 2  INTC 0D
       NO ACTIVE MODULE FOUND
       NAME=UNKNOWN
       DATA AT PSW  0637113A - 58108014  0A0D58C0  549C9180
       GR 0: 000002B5_06371140   1: 00000000_80C03000
          2: 00000000_86371128   3: 00000000_00AFC140
          4: 00000000_7F788600   5: 00000000_7F665058
          6: 00000000_06370EEA   7: 00000000_7F788600
          8: 00000000_06371E00   9: 00000000_00AFF1C0
          A: 00000000_00AFC140   B: 00000000_00FDEA40
          C: 00000000_00AFC140   D: 00000000_00AFC1AC
          E: 00000000_00DD0DC0   F: 00000000_00000004
    END OF SYMPTOM DUMP
    

Local fix

  • keep input data on dasd or avoid using multi-volume tape as
    input
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM Component(s)    *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABENDC03 may be encountered during      *
    *                      termination of OMPE Batch Accounting    *
    *                      Report.                                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    OMPE Batch Reporter did not explicitly close ACRPTDD file.
    In some circumstances with multi-volume tape data sets in use
    this may result in ABENDC03 when z/OS attempts to close ACRPTDD
    after FPECMAIN termination.
    

Problem conclusion

  • Code changed to fix this problem.
    
    KEYWORDS:
    ABENDC03 OMPE BATCH ACCOUNTING REPORT
    Code changed to fix this problem.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI72345

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-11-15

  • Closed date

    2017-05-01

  • Last modified date

    2017-06-02

  • APAR is sysrouted FROM one or more of the following:

    PI71445

  • APAR is sysrouted TO one or more of the following:

    UI46873

Modules/Macros

  •    DGOACREP
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R540 PSY UI46873

       UP17/05/03 P F705

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
02 June 2017