IBM Support

PI71192: STACK YES INCLUDED ON IMAGE COPY TEMPLATE FOR LOB OBJECT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The STACK YES parameter may be incorrectly included on the image
    copy template for a LOB object when generating a reorg utility
    and using a tape device for image copy .  This can occur if the
    auxiliary tablespace was implicitly created by using
    SET CURRENT RULES = 'STD' on the create of the base table.
    If AUX YES is used (or defaulted) on the Reorg, the STACK YES
    parameter can lead to a S513 abend when the Reorg is executed.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Automation Tool for z/OS        *
    ****************************************************************
    * PROBLEM DESCRIPTION: The STACK YES parameter may be          *
    *                      incorrectly included on the image       *
    *                      copy template for a LOB object when     *
    *                      generating a reorg utility and using    *
    *                      a tape device for image copy . This     *
    *                      can occur if the auxiliary tablespace   *
    *                      was implicitly created by using         *
    *                      SET CURRENT RULES = 'STD' on the        *
    *                      create of the base table.               *
    *                      If AUX YES is used (or defaulted) on    *
    *                      the Reorg, the STACK YES parameter      *
    *                      can lead to a S513 abend when the       *
    *                      Reorg is executed.                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Code has been changed to fix this problem
    

Problem conclusion

  • Apply the PTF for problem resolution
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI71192

  • Reported component name

    DB2 AUTOMATION

  • Reported component ID

    5697G6300

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-10-24

  • Closed date

    2016-12-05

  • Last modified date

    2017-01-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI43115

Modules/Macros

  •    HAA#UTED HAA#UTOB
    

Fix information

  • Fixed component name

    DB2 AUTOMATION

  • Fixed component ID

    5697G6300

Applicable component levels

  • R420 PSY UI43115

       UP16/12/20 P F612

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
12 February 2021