A fix is available
APAR status
Closed as program error.
Error description
The STACK YES parameter may be incorrectly included on the image copy template for a LOB object when generating a reorg utility and using a tape device for image copy . This can occur if the auxiliary tablespace was implicitly created by using SET CURRENT RULES = 'STD' on the create of the base table. If AUX YES is used (or defaulted) on the Reorg, the STACK YES parameter can lead to a S513 abend when the Reorg is executed.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Automation Tool for z/OS * **************************************************************** * PROBLEM DESCRIPTION: The STACK YES parameter may be * * incorrectly included on the image * * copy template for a LOB object when * * generating a reorg utility and using * * a tape device for image copy . This * * can occur if the auxiliary tablespace * * was implicitly created by using * * SET CURRENT RULES = 'STD' on the * * create of the base table. * * If AUX YES is used (or defaulted) on * * the Reorg, the STACK YES parameter * * can lead to a S513 abend when the * * Reorg is executed. * **************************************************************** * RECOMMENDATION: * **************************************************************** Code has been changed to fix this problem
Problem conclusion
Apply the PTF for problem resolution
Temporary fix
Comments
APAR Information
APAR number
PI71192
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-10-24
Closed date
2016-12-05
Last modified date
2017-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI43115
Modules/Macros
HAA#UTED HAA#UTOB
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R420 PSY UI43115
UP16/12/20 P F612
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"","label":""}}]