A fix is available
APAR status
Closed as program error.
Error description
Keywords: FPECMAIN DB2PE DB2PM truncated truncation DB2PMFACCT_GENERAL FPEC4035W long strings . Customer running FPECMAIN to extract SMF records to load into DB2PMFACCT_GENERAL table sees truncation of data when receiving FPEC4035W MORE THAN 100000 UNIQUE LONG STRINGS QUALIFYING FOR UNIQUE NAME PROCESSING FOUND IN THE INPUT DATA. . THIS CAN INDICATE AN INPUT DATA PROBLEM. UNIQUE NAME PROCESSING HAS BEEN SUSPENDED TO PREVENT PERFORMANCE DEGRADATION." . long names processing was stopped and after this short names were put in reports and FILE output instead of long ones.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - Batch Reporting * **************************************************************** * PROBLEM DESCRIPTION: 1. FPEC4035W message may appear * * prematurely in OMPE Batch Reporter JOB * * SUMMARY LOG because related counter * * mistakenly incremented in attempt to * * register already registered long * * string. * * * * 2. Truncated or unique strings have * * been externalized to VARCHAR type * * fields of ACCOUNTING FILE instead of * * available long strings. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: 1. FPEC4035W message may appear prematurely in OMPE Batch Reporter JOB SUMMARY LOG because related counter mistakenly incremented in attempt to register already registered long string. That may cause truncated short names appear in reports instead of unique short names. 2. Truncated or unique short names have been externalized to VARCHAR type fields of ACCOUNTING FILE instead of available DB2 provided long names. That may complicate aggregation short identifiers mapping to their original long names. PROBLEM CONCLUSION: The code has been changed to fix these problems. KEYWORDS: OMPE BATCH ACCOUNTING REPORT FILE FPEC4035W
Problem conclusion
The code has been changed to fix these problems.
Temporary fix
Comments
APAR Information
APAR number
PI70070
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-10-03
Closed date
2017-03-20
Last modified date
2017-06-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI45703 UI45704 UI45705 PI79525
Modules/Macros
DGOAFBUF DGOAFDDF DGOAFGBP DGOAFGEN DGOAFISA DGOAFPCK FPECHE15 FPEUFLNS FPEUFLN2 FPEUIFCI FPEUIFC2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R511 PSY UI45703
UP17/03/24 P F703
R520 PSY UI45704
UP17/03/24 P F703
R530 PSY UI45705
UP17/03/24 P F703
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: