Error description

  • When Query Monitor sends (QM) a workload to Query Workload Tuner
    (QWT) for tuning, QM has to tell QWT what database connection to
    use in order to access the EXPLAIN tables. QM will provide
    connection information for a member that QM selects, regardless
    of whether DDF is enabled for that member. If the member that QM
    selects does not have DDF enabled, then workload tuning will
    fail.
    .
    This APAR will do two things:
      1. Users will be able to select, from a "Monitored Database"
    menu in QM, which member of the datasharing group should be used
    for the database connection in QWT when tuning this workload.
      2. If the "Staging Table Connection" the user selects in QM is
    a connection to a member in the datasharing group, then the menu
    mentioned will default to the member that is used for the
    staging table connection.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM DB2 Query Monitor z/OS.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: When Query Monitor sends (QM) a         *
    *                      workload to Query Workload Tuner (QWT)  *
    *                      for tuning, QM has to tell QWT what     *
    *                      database connection to use in order to  *
    *                      access the EXPLAIN tables. QM will      *
    *                      provide connection information for a    *
    *                      member that QM selects, regardless      *
    *                      of whether DDF is enabled for that      *
    *                      member. If the member that QM selects   *
    *                      does not have DDF enabled, then         *
    *                      workload tuning will fail.              *
    *                      This APAR will do two things:           *
    *                        1. Users will be able to select,      *
    *                         from a "Monitored Database" menu in  *
    *                         QM, which member of the datasharing  *
    *                         group should be used for the         *
    *                         database connection in QWT when      *
    *                         tuning this workload.                *
    *                        2. If the "Staging Table Connection"  *
    *                         the user selects in QM is a          *
    *                         connection to a member in the        *
    *                         datasharing group, then the menu     *
    *                         mentioned will default to the        *
    *                         member that is used for the          *
    *                         staging table connection.            *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI67278

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-08-09

  • Closed date

    2016-10-17

  • Last modified date

    2016-11-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI41736

Modules/Macros

  • CQMBLOB  CQMCAEPT CQMCPXPT CQMJAR
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R320 PSY UI41736

       UP16/10/20 P F610

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0"}]

Document Information

Modified date:
17 March 2021