Error description
It is possible to get 'CKZ27140E DSNJU003 UTILITY EXECUTION FAILED' from the DB2ALTERBSDS SLB-START command. An incorrect value can be used for the ENDLRSN value in the creation of the conditional restart record. This can happen when the BSDS supports extended RBA/LRSN and there are more than 50 SLB records. The DSNJU003 utility puts out message: DSNJ407I DSNRJFCK WARNING - NO VALID CHECKPOINT RBA FOUND. LOG WILL BE SCANNED AT RESTART
Local fix
A ZAP can be provided.
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM DB2 Cloning Tool z/OS. * **************************************************************** * PROBLEM DESCRIPTION: It is possible to get 'CKZ27140E * * DSNJU003 UTILITY EXECUTION FAILED' * * from the DB2ALTERBSDS SLB-START * * command. An incorrect value can be * * used for the ENDLRSN value in the * * creation of the conditional restart * * record. This can happen when the BSDS * * supports extended RBA/LRSN and * * there are more than 50 SLB records. * * The DSNJU003 utility puts out message: * * DSNJ407I DSNRJFCK WARNING - NO VALID * * CHECKPOINT RBA FOUND. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PI66200
Reported component name
DB2 CLONING TOO
Reported component ID
5655N1000
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-07-20
Closed date
2016-09-21
Last modified date
2016-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI40930
Modules/Macros
CKZ00221
Fix information
Fixed component name
DB2 CLONING TOO
Fixed component ID
5655N1000
Applicable component levels
R320 PSY UI40930
UP16/09/28 P F609
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]