IBM Support

PI66200: POSSIBLE CKZ27140E ERROR FROM THE DB2ALTERBSDS SLB-START COMMAND

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • It is possible to get 'CKZ27140E DSNJU003 UTILITY EXECUTION
    FAILED' from the DB2ALTERBSDS SLB-START command.
    An incorrect value can be used for the ENDLRSN value in the
    creation of the conditional restart record.
    This can happen when the BSDS supports extended RBA/LRSN and
    there are more than 50 SLB records.
    The DSNJU003 utility puts out message:
    DSNJ407I  DSNRJFCK WARNING - NO VALID CHECKPOINT RBA FOUND.
    LOG WILL BE SCANNED AT RESTART
    

Local fix

  • A ZAP can be provided.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM DB2 Cloning Tool z/OS.          *
    ****************************************************************
    * PROBLEM DESCRIPTION: It is possible to get 'CKZ27140E        *
    *                      DSNJU003 UTILITY EXECUTION FAILED'      *
    *                      from the DB2ALTERBSDS SLB-START         *
    *                      command. An incorrect value can be      *
    *                      used for the ENDLRSN value in the       *
    *                      creation of the conditional restart     *
    *                      record. This can happen when the BSDS   *
    *                      supports extended RBA/LRSN and          *
    *                      there are more than 50 SLB records.     *
    *                      The DSNJU003 utility puts out message:  *
    *                      DSNJ407I  DSNRJFCK WARNING - NO VALID   *
    *                      CHECKPOINT RBA FOUND.                   *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI66200

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-07-20

  • Closed date

    2016-09-21

  • Last modified date

    2016-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI40930

Modules/Macros

  • CKZ00221
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R320 PSY UI40930

       UP16/09/28 P F609

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: