IBM Support

PI65708: DIFFERENT SQL GENERATED FOR DYNAMIC CUBE REPORT BETWEEN HTML ANDEXCEL 2007

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as suggestion for future release.

Error description

  • When running a crosstab report with many calculations, the
    generated SQL between HTML and Excel 2007 is different. Excel is
    generating 13 queries, whereas HTML is generating 29 queries,
    resulting in a faster performance for Excel 2007 outputs.
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • The report when runs as HTML works as designed and returned the
    expected numbers of SQLs.
    
    When a report was run and saved as HTML, by default, it is
    expected from the report to perform drill-up/-down,
    drill-through and other interactive actions once the report was
    saved and opened in Report Viewer.
    The interactivity of the HTML report causes that the additional
    properties were created in the requests which may cause slower
    return of the report results.
    
    When the user does not require the HTML interactivity in the
    saved report, by disabling the selection-based interactivity
    feature the report will run faster and in this case will create
    the same number of SQLs as when the same report was run as Excel
    2007 (or PDF).
    To disable the HTML interactivity, the option "Enable
    selection-based interactivity" should be checked-out in
    Properties for the Report (or in Advanced options). For detail
    please check the section "Disable Selection-based Interactivity"
    (Page 95) in the document:
    http://data.ucop.edu/files/documents/cognos-connection-10.2.2.pd
    f
    

APAR Information

  • APAR number

    PI65708

  • Reported component name

    COG REPORT STUD

  • Reported component ID

    5724W12RS

  • Reported release

    A22

  • Status

    CLOSED SUG

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-07-12

  • Closed date

    2016-10-14

  • Last modified date

    2016-10-14

  • APAR is sysrouted FROM one or more of the following:

    PI64179

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHNWW","label":"Report Authoring v11x"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A22","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: