Fixes are available
APAR status
Closed as program error.
Error description
The HTTP transport has a configuration setting for "Max connections per host". This limits the number of outgoing connections to the host configured. This setting is remaining at the default of 20. SYMPTOMS: When running a performance test against a web service that responds slowly, for example in 500ms, only 40TPS can be achieved per test engine. HTTP connections are unable to be started until existing ones are completed. WORKAROUND: Run multiple test engines to increase load throughput.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of Rational Integration Tester working with HTTP * * Transport * **************************************************************** * PROBLEM DESCRIPTION: * * The HTTP transport has a configuration setting for "Max * * connections per host". This limits the number of outgoing * * connections to the host configured. This setting is * * remaining * * at the default of 20. * * * * SYMPTOMS: * * * * When running a performance test against a web service that * * responds slowly, for example in 500ms, only 40TPS can be * * achieved per test engine. HTTP connections are unable to be * * started until existing ones are completed. * * * * WORKAROUND: * * * * Run multiple test engines to increase load throughput. * **************************************************************** * RECOMMENDATION: * * Upgrade to Rational Integration Tester v9.0.0.1 which * * includes a fix for this issue * ****************************************************************
Problem conclusion
A fix for this issue was provided in version 9.0.0.1 of Rational Integration Tester.
Temporary fix
Comments
APAR Information
APAR number
PI61507
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-04-27
Closed date
2016-05-24
Last modified date
2016-05-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"900","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
15 October 2021