A fix is available
APAR status
Closed as program error.
Error description
When the OMEGAMON Collector is running and option auto detect is activated for the PE Server subtask, the PE Server subtask load module DGOVMSTR abends with system completion code S0C4. Monitoring of the DB2 subsystems is no longer possible. . Abend S0C4-11 in DGOVMSTR +127A V530 due to R12 is bad. The 0C4-11 occurred as the SSCTSUSE field (R12) didn't contain a valid address.Then OMPE terminated with CI0970: OMEGAMON SUBTASK ABEND CODE=0000012C PSW=078D2000A33F23E2 TCB=008C75A8 CI0971: PROGRAM NAME=DGOVMSTR KO2Z663I OM00 V530 PESERVER Subtask DGOVMSTR Restart *Skipped* RC=0000 RSN=00000000 TCB=0000012C . SYSTEM COMPLETION CODE=0C4 REASON CODE=00000011 TIME=14.51.58 SEQ=32291 CPU=0000 ASID=01ED PSW AT TIME OF ERROR 078D0000 A33F2C82 ILC 6 INTC 11 ACTIVE LOAD MODULE ADDRESS=233F1A08 OFFSET=0000127A NAME=DGOVMSTR DATA AT PSW 233F2C7C - 000F58C0 A318D503 C00454D5 GR 0: 00F40B80_00000000 1: 00000000_233E7E30 2: 00000000_00000000 3: 00000000_00CE5AD0 4: 00000000_233E80FB 5: 00000000_233F65B8 6: 00000000_00000001 7: 00000000_233E7F58 8: 00000000_00000000 9: 00000000_00000009 A: 00000000_233E7C40 B: 00000000_A33F2C1A C: 00000000_80C8C3C9 D: 00000000_233E7C40 E: 00000000_A33F2C78 F: 00000000_00000000 .
Local fix
Disable AUTODETECT in RKD2PAR(OMPEMSTR)
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - PE Server subtask * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4-11 in DGOVMSTR * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: ABEND0C4 received attempting to validate subsystem control blocks. The collector started task will then terminate with MSGKO2Z663I OM00 V530 PESERVER Subtask DGOVMSTR Restart *Skipped* RC=0000 RSN=00000000 TCB=0000012C and MSGKO2Z091E OM00 V530 Collector address space terminating due to PESERVER failure PROBLEM CONCLUSION: Added additional recovery. KEYWORDS: ABEND0C4 DGOVMSTR
Problem conclusion
Added additional recovery.
Temporary fix
Comments
APAR Information
APAR number
PI59283
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-18
Closed date
2016-04-07
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI36859 UI36860 UI36861
Modules/Macros
DGOVMSTR FPEVTMEM
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R511 PSY UI36859
UP16/04/09 P F604
R520 PSY UI36860
UP16/04/09 P F604
R530 PSY UI36861
UP16/04/09 P F604
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
04 February 2017