IBM Support

PI58880: RHAPSODY GENERATES SOFTWARE THAT DOES NOT BUILD WHEN FLOWPORTS USE "UNSIGNED" DATATYPES.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Rhapsody generates software that does not build when flowports
    use "unsigned" datatypes (e.g., unsigned char, unsigned int).
    This appears limited to when you generate C code.
    
    The model builds fine when you generate C++ or use the microC
    profile.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Rhapsody users                                               *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Auto generated code for RiC flowports when data type         *
    * contains space, such as "unsigned char", generates partial   *
    * function name and cause compilation error.                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed in Rhapsody 8.2 - The space is now removed from the auto
    function name.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI58880

  • Reported component name

    TLOGIC RHAPSODY

  • Reported component ID

    5724V74RP

  • Reported release

    812

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-03-10

  • Closed date

    2016-12-05

  • Last modified date

    2016-12-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC RHAPSODY

  • Fixed component ID

    5724V74RP

Applicable component levels

  • R814 PSN

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
05 December 2016