IBM Support

PI58702: IMS BMP Jobs may abend with U0002 and IMS Control Region could abend with U4095

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Prior to APAR PI58702 the Guardium encryption exit routines
    DECENA01, DECENB01, and DECENC01 always added one byte of
    control information when IMS data was encrypted. This caused
    the following implementation concerns-
    º  For uncompressed variable length segments, the maximum
    segment size in the DBD had to be increased by 1 when the
    COMPRTN was added to allow for the additional byte of data when
    encrypting a maximum length segment.
    º  For compressed variable or fixed length segments, if the
    compressed data length was equal to the DBD maximum variable
    length segment size, or the fixed length segment size plus 10,
    it is not possible to add the additional byte of data when
    encrypting it and an exit failure will occur.
    APAR PI58702 removes the addition of the one byte of control
    data to address the implementation concerns. This change,
    however, is an incompatible change. Any IMS data encrypted
    using an exit built with a pre-PI58702 level of DECENA01,
    DECENB01, or DECENC01 code can not be properly decrypted using
    an exit built with the PI58702, or later, level of code if the
    documented migration actions are not performed.
    Migration Actions
    If an existing exit built with a pre-PI58702 level of DECENA01,
    DECENB01, or DECENC01 must be rebuilt with the PI58702, or
    later, level of code the following migration actions must be
    performed for the data to be properly decrypted with the
    rebuilt exit-
    1. Unload all of the data that has been encrypted using an exit
    built with a pre-PI58702 level of code. The data must be
    decrypted when it is unloaded.
    2. Rebuild the exit using the PI58702, or later, level of code.
    3. Reload all of the data using the rebuilt exit.
    
    IMS BMP Jobs may abend with U0002 and also cause the IMS
    Control Region to abend with U4095.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM InfoSphere Guardium Data Encryption  *
    *                 for DB2 and IMS Databases Version 1 Release  *
    *                 2 users.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS BMP jobs may abend with U0002 and   *
    *                      also cause the IMS Control Region to    *
    *                      abend with U4095                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    IMS BMP jobs may abend with U0002 and also cause the IMS Control
    Region to abend with U4095.
    

Problem conclusion

  • 1. After successful SMP/E apply, the Modules DECENA01,
    DECENB01, and DECENC01, are updated.
    2. After successful SMP/E apply, if Customer wishes to use the
    DECENA01, DECENB01, or DECENC01 Modules, they should execute the
    necessary link samplib member and verify that their IMS Exit
    library is refreshed. Execute DECIMSCK, for DECENA01.  Execute
    DECIMSCB, for DECENB01.  Execute DECIMSSK, for DECENC01.
    3. Customer should note that changes have been made to the
    SDECCEXE library, to use PI58702, in the ISPF Panels.
    4. Customer should note that IMS Exits, linked with DECENA01,
    DECENB01, and DECENC01, which use an Error Key, will have new
    error messages, which indicate the problem cause, issued either
    in the DLI Batch Output, or for BMP   issued in the IMS DLI and
    System Log outputs.  The Messages:  DEC0001E, DEC0002E,
    DEC0003E, DEC0004E, DEC0005E, and DEC0006E.
    5. After successful linking of the DEC V1.2 DECENA01, DECENB01,
    and DECENC01 Modules, for this APAR, Customer should do either
    of the following actions:
    
    a.  Determine if the IMS EXIT library, for the IMS Subsystem
    where DEC V1.2 is used, is in the System Linklist concatenation.
    If so, issue the LLA Refresh command on that System LPAR.
    This will allow Customer to use the updated code, without need
    to Cycle the IMS Subsystem.
    b.  If the IMS EXIT library, for the IMS Subsystem where
    DEC V1.2 is used, is not in the System Linklist concatenation,
    Customer will need to Cycle the IMS Subsystem, in order to
    use the updated code.
    
    New Messages - Coming in a Future Doc update:
    DEC0001E DECENxx1 encryption exit error.
    
    DEC0002E Function: funcname Function code: 000000nn
    
    DEC0003E ICSF debug data:
    
    DEC0004E Retcode: 000000xx Reason code: xxxxxxxx
    
    DEC0005E Key len: 000000xx Text length: xxxxxxxx
    
    DEC0006E The IMS U2990 message also displays a reason code.
    

Temporary fix

Comments

  • ×**** PE16/09/01 FIX IN ERROR. SEE APAR PI68520  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PI58702

  • Reported component name

    DATA ENCRYPTION

  • Reported component ID

    5655P0300

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-03-07

  • Closed date

    2016-07-21

  • Last modified date

    2017-03-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI39585

Modules/Macros

  • DECENA01 DECENB01 DECENC01 DECENC07
    

Fix information

  • Fixed component name

    DATA ENCRYPTION

  • Fixed component ID

    5655P0300

Applicable component levels

  • R120 PSY UI39585

       UP16/07/29 P F607 Ø

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: