IBM Support

PI58401: SYSTEM ABEND 0C4 REASON CODE X'11' OCCURRED IN MODULE HKTDAPI0 CSECT HKTDBLDB (AKA DISCOVERY UTILITY) AT OFFSET X'7F0'

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HKTDBLDB, offset X'7F0': Abend S0C4-X'11' occurs, when HALDB
    master DBD name is registered but no PART is registered in the
    RECON data sets.
    additional keyword HKTDISCO
    

Local fix

  • It is recommended to do INIT.PART to correct and avoid the 0c4
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IBM Tools Base for z/OS V1.5 users who run   *
    *                 the IMS Tools Discovery Utility (HKTDDSCO),  *
    *                 or who use Autonomics Director client        *
    *                 interface on ISPF                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: When HALDB partition or DEDB area is    *
    *                      not registered to RECON,  the IMS       *
    *                      Tools Discovery Utility (HKTDDSCO)      *
    *                      gets system abend 0C4 reason code       *
    *                      X'11', and the Autonomics Director      *
    *                      (for IMS) server gets system abend      *
    *                      0C4 in the module IAVDSAD3.             *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    HKTDDSC0 abend 0C4 occurs in one of the following conditions:
    - HALDB PART is not registered to RECON
    - DEDB ADS or DBDS is not registered to RECON
    Autonomics Director server abend 0C4 occurs in the following
    condition:
    - HALDB PART is not registered to RECON, and Add or Expand is
    selected for the HALDB during managing monitor list in the
    Autonomics Director client interface on ISPF.
    

Problem conclusion

  • System ABEND 0C4 is resolved by checking RECON record is
    strengthened. The following actions will be taken
    after 0C4 is resolved:
    
    HKTDDSC0
    
     - When HALDB master DBD or PART is not registered to
       RECON, HKTDDSC0 issues HKTD494W message,
       skips the database, and continue processing the
       other databases.
       HKTD494W VALIDATION FAILED - DBD xxxxxxxx SKIPPED
    
     - When DEDB ADS or DBDS is not registered to RECON,
       HKTDDSC0 processes the DEDB with retrieving the
       information from DBD instead of RECON.
    
    Autonomics Director Server
    
     - When HALDB master DBD or PART is not registered to RECON
      and Add or Expand is selected for the HALDB during managing
       monitor list, HKTDAPI GET PARTITION DATA FROM RECON FAILED
       message appears on ISPF panel and Add or Expand failed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI58401

  • Reported component name

    TOOLS BASE

  • Reported component ID

    5655V9300

  • Reported release

    150

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-03-02

  • Closed date

    2016-03-14

  • Last modified date

    2016-04-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI36172

Modules/Macros

  •    HKTDBLDB HKTDDBD0 HKTDWRDB IAVDSAD3
    

Fix information

  • Fixed component name

    TOOLS BASE

  • Fixed component ID

    5655V9300

Applicable component levels

  • R150 PSY UI36172

       UP16/03/16 P F603

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IBM Tools Base"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.5.0"}]

Document Information

Modified date:
19 October 2020